Graco Inc ti15036a, 795 Premium Hi, 695 Premium Hi, 3A0156A, ti14838a Pressure Relief Procedure

Page 8

15/20 Amp Switch (Not Available on All Units)

15/20 Amp Switch (Not Available on All Units)

ti14919a

Select 15A or 20A setting based on your circuit rating.

Pressure Relief Procedure

1.Turn power OFF. Wait 7 seconds for power to dissipate.

ti4265a

2.Lock gun trigger safety. Remove guard and SwitchTip.

3.Turn pressure to lowest setting. Trigger gun to relieve pressure.

-

ti14841a

 

4.Put drain tube in pail. Turn prime valve down to DRAIN position.

ti14842a

ti2595a

ti10166ati2769a

8

3A0156A

Image 8
Contents Electric Airless Sprayers 3A0156AModels Ultra MAX lIlGrounding Instructions Fire and Explosion Hazard Equipment Misuse Hazard Component Identification Grounding PailsPressure Relief Procedure Setup Startup 15secSwitch Tip Installation SprayWatchDog Protection Fast FlushHose Reel Not Available on All Units Digital Tracking System Not Available on All Units Code Number Models Cleanup Pump Armor Technical Data Dimensions3A0156A Warranty For Graco Canada Customers