Graco Inc 244592, 309298J, TI1713A, PRO Auto Xs AA Electrical Tests, Test Gun Resistance

Page 29

Electrical Tests

Electrical components inside the gun affect performance and safety. The following procedures test the condition of the power supply (12) and barrel (6), and electrical continuity between components.

CAUTION

The barrel resistor cartridge is part of the barrel and is not replaceable. To avoid destroying the gun barrel, do not attempt to remove the barrel resistor.

Use megohmmeter Part No. 241079 (AA) and an applied voltage of 500 V. Connect the leads as shown.

Electrical Tests

Test Gun Resistance

1.Flush and dry the fluid passage.

2.Measure resistance between the electrode needle tip (40a) and the turbine air inlet fitting (TA); it should be 156-180 megohms. If outside this range, relieve pressure and remove the air cap (page 37). Inspect the electrode (40a) and the barrel conductive ring (6a) for damage and proper position, to ensure that the electrode makes contact with the conductive ring. Reinstall the air cap and repeat the measure- ment. If it is still outside this range, remove the gun for service.

TA

WARNING

Fire, Explosion, and Electric Shock Hazard

Megohmmeter Part No. 241079 (AA-see FIG. 19.) is not approved for use in a haz- ardous area. To reduce the risk of sparking, do not use the megohmmeter to check elec- trical grounding unless:

The gun has been removed from the haz- ardous area;

Or all spraying devices in the hazardous area are turned off, ventilation fans in the hazardous area are operating, and there are no flammable vapors in the area (such as open solvent containers or fumes from spraying).

Failure to follow this warning could cause fire, explosion, and electric shock and result in serious injury and property damage.

AA

TI1739A

40a

TA

TI1733B

Fig. 19. Test Gun Resistance

309298J

29

Image 29
Contents Important Safety Instructions Instructions/Parts ListSee page 2 for Table of Contents II 2 G EEx 0.24MJTable of Contents Fire, Explosion, and Electric Shock Hazard SymbolsToxic Fluid Hazard Skin Injection HazardEquipment Misuse Hazard Introduction Gun Features and OptionsHow the Electrostatic AA Spray Gun Works Operating the Spray FunctionKV1 Air KV2 Air Output Voltage kV Changing the kV SettingKV1 and KV2 Switch Settings Manifold Markings TI1714A Manifold Back ViewVentilate the Spray Booth InstallationInstall the System Non-Hazardous Area Non-Hazardous Area Manifold Back ViewInstall the Fluid Line Accessories Install the Air Line AccessoriesComponent Rupture Hazard Skin Injection HazardMounting Bracket Install the Gun and Mounting BracketManifold Connections Connect the Air and Fluid LinesElectric Shock Hazard Supply HoseFiber Optic Fitting Optional Fiber Optic Cable ConnectionGrounding Check Gun Grounding Check Electrical GroundingCheck Fluid Viscosity Install the Fabric CoverCheck Fluid Resistivity Operating Checklist Pressure Relief ProcedureRelief Procedure at left OperationSelect a Spray Tip Install the Spray TipPressurized Equipment Hazard Set the Atomization Fluid PressurePsi 21 MPa, 210 bar CorrectTurbine Air Air pressure at turbine air hose Hose Length Adjust the ElectrostaticsDynamic Turbine Air Pressures Triggering the Fluid Alone SprayingShutdown Fire and Explosion HazardDaily Care and Cleaning MaintenanceDo not point the gun up while cleaning it Do not immerse the gun in fluidFire, Explosion, and Electric Shock Hazard Remove Spray Tip Before Flushing Flush the Spray GunEquipment Needed Clean the Spray GunProcedure Clean the Inline Fluid Filter Check for Fluid Leakage Skin Injection Hazard Check for Fluid LeakageTest Gun Resistance Electrical TestsTest Power Supply Resistance Test Power Supply ResistanceTest Barrel Resistance Test Barrel ResistanceSpray Pattern Troubleshooting TroubleshootingGun Operation Troubleshooting See Test Gun Resistance on Electrical TroubleshootingSee Check Electrical Grounding on 16 and Test Gun ResistanceRepair Prepare the Gun for ServiceRemove the Gun from the Manifold Install the Gun on the ManifoldTip Guard, Air Cap, and Spray Tip Replace- ment Tip Guard, Air Cap, Spray Tip, or Seat Housing ReplacementRepair Electrode Replacement Electrode ReplacementFluid Filter Removal Fluid Tube ReplacementNot overtighten Fluid Needle ReplacementPiston O-Rings Piston RepairActuator Arm Adjustment Adjust the Actuator ArmBarrel Removal Barrel RemovalBarrel Installation Barrel InstallationPower Supply Removal and Replacement Power Supply Turbine Alternator Removal and ReplacementRef. No Alternator Detail PartsPart No PRO Auto Xs AA Electrostatic Gun, Series a Description Qty Plug Fan Width at Orifice Size Spray Tip Selection ChartGun Accessories AccessoriesAir Line Accessories Fluid Line AccessoriesPaint Probe Safety Warning SignsES Display Module Fiber Optic Y CablesAccessories 309298J Category Data Technical DataToll Free Graco Standard WarrantyGraco Information

244592, PRO Auto Xs AA, TI1713A, 309298J specifications

Graco Inc is a renowned brand in the field of fluid handling systems and accessories, with a reputation for delivering high-quality products that serve a variety of industries, including automotive, construction, and manufacturing. Among their extensive lineup, the Graco 309298J, TI1713A, PRO Auto Xs AA, 244592 represents a significant advancement in spray technology, notably regarded for its efficiency and versatility.

The Graco 309298J model is a part of the PRO Auto Xs series, designed specifically for high-performance spray applications. One of the standout features of this equipment is its auto-adjusting technology, which automatically adapts the spray pattern based on the surface being coated. This ensures uniform coverage and reduces the waste of material, making it an environmentally friendly option.

Equipped with an ergonomic design, the PRO Auto Xs AA enhances user comfort and reduces fatigue during prolonged use. The lightweight construction makes it easy to handle, while the balanced design allows for precise control, ensuring that even intricate spray patterns can be achieved with minimal effort.

Technologically, this spray gun incorporates advanced fluid dynamics that allow it to produce fine atomization, resulting in a superior finish. The easy-to-clean design coupled with a durable construction ensures that maintenance is straightforward, which is crucial for professionals who require reliability under demanding conditions.

Another notable characteristic is the Graco TI1713A tip, which is compatible with a variety of coatings, including paint, stains, and sealers. This versatility allows users to switch seamlessly between different materials without the need for extensive reconfiguration. The adjustability of the spray width further adds to its functionality, enabling operators to customize the application based on the job requirements.

Additionally, the 244592 model is designed with safety features, such as anti-drip mechanisms and pressure control valves, ensuring safe operation. Graco's commitment to quality is evident in the durability of its products, as they withstand the rigors of daily use while delivering consistent performance over time.

In summary, the Graco 309298J Pro Auto Xs AA, 244592 is a sophisticated spray solution that showcases the fusion of advanced technology and user-centric design, catering to professionals seeking efficiency, versatility, and reliability in their spray applications. This model stands out as an essential tool for anyone looking to enhance their workflow and achieve exceptional finish quality.