Graco Inc G40, 311052E, 288046, 288217 important safety instructions Setup

Page 11

Setup

Flush Spray Gun

Before running any paint through the spray gun:

1.Flush the gun with a solvent that is compatible with the fluid to be sprayed, using the lowest possible fluid pressure and grounded metal container.

2.Perform Pressure Relief Procedure; see page 12.

Select a Spray Tip and Air Cap

The fluid flow and pattern width depend on the size of the spray tip, the fluid viscosity, and the fluid pressure. See page 31 and page 32 for spray tip selection charts. Contact your Graco distributor for assistance in select- ing an appropriate spray tip for your application.

Install a Spray Tip

1.Perform Pressure Relief Procedure, page 12.

2.Install a spray tip in the gun.

3.Align tip locating tab with slot on the air cap. See FIG. 7.

4.Tighten the air cap retaining ring (8) firmly by hand to ensure a good seal between the tip gasket and the diffuser (10).

Slot

Tip Locating Tab

TI6847A

FIG. 7

Setup

Position the Air Cap

The air cap and spray tip position determines the direc- tion of the spray pattern.

Rotate the air cap (the spray tip rotates with it) as needed to achieve the desired spray pattern direction. See FIG. 8.

TI6558A

FIG. 8

Air Cap Alignment Pin

Air caps are factory-set with an air cap alignment pin to position the air cap. The standard location of the air cap alignment pin is the vertical spray pattern.

To change the spray pattern direction, use a needle nose pliers to unscrew the pin and relocate it to the desired position. See FIG. 9. When relocating the pin use low-strength thread locker. Torque to 1.5-2.5 in-lb (0.2-0.3 N•m). Do not overtighten.

Horizontal

Air Cap Position

(standard)

Vertical

 

Air Cap Position

TI6847A

FIG. 9

311052E

11

Image 11
Contents Automatic G40 Air-Assisted Spray Guns Related Manuals ContentsG40 RAC Spray Gun, 288053, Series a ModelsG40 Standard Spray Gun, 288046, Series a G40 Plastic Seat Spray Gun, 288044, Series BEquipment Misuse Hazard Pressurized Equipment Hazard Circulating System InstallationVentilate Spray Booth Configure Gun and ManifoldGround System Install Air FittingsRetrofit Adapter Plate Mount GunReciprocating Arm Rod Mount Stationary SupportConnect Air Line Side Mounted Manifold Ports Connect Fluid LineSetup Operation Pressure Relief ProcedureAdjust Spray Pattern No air Too little air Correct amount Air Apply FluidIncorrect CorrectDaily Gun Care MaintenanceFlushing and Cleaning General System MaintenanceTurn off the solvent supply Problem Cause Solution TroubleshootingGeneral Troubleshooting Problem Cause Solution Spray Pattern Troubleshooting Items Needed for Service ServiceDisassembly TI8173b Cutaway View Part No Gun Shown Reassembly Diffuser Seat ReplacementParts AA RAC Assembly included with Model 288053 onlyPart Ref. No. No Description Qty PartsNorth America and International Manifold Description QtyManifold with Bottom Fluid Ports Part No. Description QtyPart No C343 Side Fluid Ports and Fan Adjustment ValveRING, Ptfe 311052E Typical Air Application Tip Used With Consumption AAP Series Tip and Air Cap Selection ChartsAAP Series Precision Spray Tips LTX Reverse-A-Clean RAC Spray Tips LTX Series RAC Tip Selection ChartsFor use with G40 RAC Housing WRX Wide RAC Spray Tips RAC Switch TipsFFT Fine Finish RAC Spray Tips Accessories Plastic Seat Repair Kit Ultimate Gun Cleaning Kit 15C161Grounding Clamp and Wire In-line Fluid Filter Air Cap Seal KitDimensions Mounting Hole Layout Gun with Rear Port Manifold Rear Port ManifoldModels 3/16 in. ball Cylinder Air Pressure Fluid Pressure Technical DataTriggering Speed Sound Data dBaGraco Information Graco Standard Warranty