Installation

Installation

Ventilate Spray Booth

Check and follow all National, State, and Local codes regarding air exhaust velocity requirements.

Check and follow all local safety and fire codes.

Configure Gun and Manifold

The gun is supplied with an internal fluid plug and seals (5, 6, 7). To use the gun in a circulating system, remove the internal plug. In a non-circulating system, leave the plug in place to minimize flush time.

Circulating System

1.Apply anti-seize lubricant 222955 to the threads and mating faces of the manifold (101) and the elbows (107), supplied unassembled.

2.Install the elbows (107) in both fluid ports of the manifold (101).

3.Connect the fluid supply line to one elbow and the fluid return line to the other. The manifold fluid ports are reversible.

4.Install the gun on the manifold, using the four screws (17). Start the threads of all four screws, and tighten the front two screws first, and then tighten the back two screws to 65 in-lb (7.3 N•m).

Non-circulating System

1.See FIG. 1. Apply anti-seize lubricant 222955 to the threads and mating faces of the manifold (101), plug (109), and elbow (107), supplied unassembled.

2.Install an elbow (107) in one fluid port of the mani- fold (101), and a plug (109) in the other port.

3.Install the internal plug (5) in the gun fluid port on the same side as the manifold plug.

4.Connect the fluid supply line to the manifold elbow (107).

5.Install the gun on the manifold, using the four screws (17). Start the threads of all four screws, and tighten the front two screws first, and then tighten the back two screws to 65 in-lb (7.3 N•m).

1

Remove when used in circulating systems.

2

Replace with a reducing nipple (107) when used in

 

circulating systems.

3

Install optional filter in fluid inlet port. See Accessories,

 

page 34.

7

3

 

6

 

 

 

101

1

5

107

 

 

2109

TI8587b

FIG. 1: Non-Circulating Setup Shown (cutaway view)

6

311052E

Image 6
Contents Automatic G40 Air-Assisted Spray Guns Contents Related ManualsG40 Plastic Seat Spray Gun, 288044, Series B ModelsG40 Standard Spray Gun, 288046, Series a G40 RAC Spray Gun, 288053, Series aEquipment Misuse Hazard Pressurized Equipment Hazard Configure Gun and Manifold InstallationVentilate Spray Booth Circulating SystemInstall Air Fittings Ground SystemStationary Support Mount GunReciprocating Arm Rod Mount Retrofit Adapter PlateConnect Air Line Connect Fluid Line Side Mounted Manifold PortsSetup Pressure Relief Procedure Adjust Spray PatternOperation Correct Apply FluidIncorrect No air Too little air Correct amount AirMaintenance Daily Gun CareGeneral System Maintenance Flushing and CleaningTurn off the solvent supply Troubleshooting General TroubleshootingProblem Cause Solution Problem Cause Solution Spray Pattern Troubleshooting Service DisassemblyItems Needed for Service TI8173b Cutaway View Part No Gun Shown Diffuser Seat Replacement ReassemblyAA RAC Assembly included with Model 288053 only PartsParts Part Ref. No. No Description QtyDescription Qty North America and International ManifoldPart No. Description Qty Manifold with Bottom Fluid PortsSide Fluid Ports and Fan Adjustment Valve Part No C343RING, Ptfe 311052E AAP Series Tip and Air Cap Selection Charts AAP Series Precision Spray TipsTypical Air Application Tip Used With Consumption LTX Series RAC Tip Selection Charts For use with G40 RAC HousingLTX Reverse-A-Clean RAC Spray Tips RAC Switch Tips FFT Fine Finish RAC Spray TipsWRX Wide RAC Spray Tips Accessories Air Cap Seal Kit Ultimate Gun Cleaning Kit 15C161Grounding Clamp and Wire In-line Fluid Filter Plastic Seat Repair KitDimensions Mounting Hole Layout Rear Port Manifold Gun with Rear Port ManifoldSound Data dBa Technical DataTriggering Speed Models 3/16 in. ball Cylinder Air Pressure Fluid PressureGraco Standard Warranty Graco Information