Graco Inc 288046, 311052E Apply Fluid, Incorrect, No air Too little air Correct amount Air

Page 13

 

 

TI0792

no air

too little air

correct amount

 

 

of air

FIG. 11: Correct Spray Pattern

Apply Fluid

The spray gun has a built-in lead and lag operation. When triggered, the gun begins emitting air before the fluid is discharged. When the trigger actuation air is stopped, the fluid stops before the air flow stops. This helps assure the spray is atomized and prevents fluid buildup on the air cap and tip.

Adjust the system control device, if it is automatic, so the gun starts spraying just before meeting the work piece and stops as soon as the work piece has passed. Keep the gun a consistent distance, 8 to 10 inches (200 to 250 mm), from the surface of the object being sprayed.

Operation

To achieve best results when applying fluid:

Keep gun perpendicular and 8 to 10 inches (200 to 250mm) from object being sprayed.

Use smooth, parallel strokes across surface to be sprayed with 50% overlap. See FIG. 12.

Incorrect

TI8098a

Correct

TI8099a

FIG. 12: Correct Spray Method

311052E

13

Image 13
Contents Automatic G40 Air-Assisted Spray Guns Related Manuals ContentsG40 Standard Spray Gun, 288046, Series a ModelsG40 Plastic Seat Spray Gun, 288044, Series B G40 RAC Spray Gun, 288053, Series aEquipment Misuse Hazard Pressurized Equipment Hazard Ventilate Spray Booth InstallationConfigure Gun and Manifold Circulating SystemGround System Install Air FittingsReciprocating Arm Rod Mount Mount GunStationary Support Retrofit Adapter PlateConnect Air Line Side Mounted Manifold Ports Connect Fluid LineSetup Adjust Spray Pattern Pressure Relief ProcedureOperation Incorrect Apply FluidCorrect No air Too little air Correct amount AirDaily Gun Care MaintenanceFlushing and Cleaning General System MaintenanceTurn off the solvent supply General Troubleshooting TroubleshootingProblem Cause Solution Problem Cause Solution Spray Pattern Troubleshooting Disassembly ServiceItems Needed for Service TI8173b Cutaway View Part No Gun Shown Reassembly Diffuser Seat ReplacementParts AA RAC Assembly included with Model 288053 onlyPart Ref. No. No Description Qty PartsNorth America and International Manifold Description QtyManifold with Bottom Fluid Ports Part No. Description QtyPart No C343 Side Fluid Ports and Fan Adjustment ValveRING, Ptfe 311052E AAP Series Precision Spray Tips AAP Series Tip and Air Cap Selection ChartsTypical Air Application Tip Used With Consumption For use with G40 RAC Housing LTX Series RAC Tip Selection ChartsLTX Reverse-A-Clean RAC Spray Tips FFT Fine Finish RAC Spray Tips RAC Switch TipsWRX Wide RAC Spray Tips Accessories Grounding Clamp and Wire In-line Fluid Filter Ultimate Gun Cleaning Kit 15C161Air Cap Seal Kit Plastic Seat Repair KitDimensions Mounting Hole Layout Gun with Rear Port Manifold Rear Port ManifoldTriggering Speed Technical DataSound Data dBa Models 3/16 in. ball Cylinder Air Pressure Fluid PressureGraco Information Graco Standard Warranty