Graco Inc 311052E, 288046 LTX Series RAC Tip Selection Charts, For use with G40 RAC Housing

Page 32

LTX Series RAC Tip Selection Charts

LTX Series RAC Tip Selection Charts

For use with G40 RAC Housing

 

* Fluid Output, fl oz/min

 

Maximum Pattern Width at 12 in. (300 mm)

 

 

(lpm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

at 2000 psi

4 to 6

 

6 to 8

8 to 10

10 to 12

 

12 to 14

Orifice Size in. (mm)

(14.0 MPa, 140 bar)

(150)

 

(200)

(250)

(300)

 

(350)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.009 (0.229)

11.2 (0.33)

209

 

309

 

 

 

 

 

 

 

 

 

 

 

 

 

0.011 (0.279)

16.6 (0.49)

211

 

311

411

511

 

 

 

 

 

 

 

 

 

 

 

0.013 (0.330)

23.3 (0.69)

213

 

313

413

513

 

 

 

 

 

 

 

 

 

 

 

0.015 (0.381)

30.8 (0.91)

215

 

315

415

515

 

615

 

 

 

 

 

 

 

 

 

0.017 (0.432)

39.5 (1.17)

217

 

317

417

517

 

617

 

 

 

 

 

 

 

 

 

0.019 (0.483)

49.7 (1.47)

219

 

319

419

519

 

619

 

 

 

 

 

 

 

 

 

0.021 (0.533)

60.5 (1.79)

 

 

321

421

521

 

621

 

 

 

 

 

 

 

 

 

0.023 (0.584)

72.7 (2.15)

 

 

 

423

523

 

623

 

 

 

 

 

 

 

 

 

0.025 (0.635)

85.9 (2.54)

 

 

 

 

525

 

625

 

 

 

 

 

 

 

 

 

0.027 (0.686)

100.0 (2.96)

 

 

 

 

527

 

627

 

 

 

 

 

 

 

 

 

0.029 (0.737)

115.6 (3.42)

 

 

 

 

 

 

629

 

 

 

 

 

 

 

 

 

0.031 (0.787)

131.8 (3.90)

 

 

 

 

531

 

631

 

 

 

 

 

 

 

 

 

* Tips are tested in water.

Pattern width measured without airflow.

LTX Reverse-A-Clean (RAC) Spray Tips

LTX RAC spray tips include a metal fluid seat and rubber fluid seal.

G40 RAC conversion kits are available. See page 32.

Housing

*†Fluid

G40 RAC Tip

Seal

Guard/Air Cap Assy.

 

 

* Fluid

 

Seat

TI8125a

* Tip Cylinder

FIG. 23

*Included with the LTX RAC spray tip.

Optional acetal fluid seal 248936 (pack of 5) available.

32

311052E

Image 32
Contents Automatic G40 Air-Assisted Spray Guns Contents Related ManualsModels G40 Standard Spray Gun, 288046, Series aG40 Plastic Seat Spray Gun, 288044, Series B G40 RAC Spray Gun, 288053, Series aEquipment Misuse Hazard Pressurized Equipment Hazard Installation Ventilate Spray BoothConfigure Gun and Manifold Circulating SystemInstall Air Fittings Ground SystemMount Gun Reciprocating Arm Rod MountStationary Support Retrofit Adapter PlateConnect Air Line Connect Fluid Line Side Mounted Manifold PortsSetup Operation Pressure Relief ProcedureAdjust Spray Pattern Apply Fluid IncorrectCorrect No air Too little air Correct amount AirMaintenance Daily Gun CareGeneral System Maintenance Flushing and CleaningTurn off the solvent supply Problem Cause Solution TroubleshootingGeneral Troubleshooting Problem Cause Solution Spray Pattern Troubleshooting Items Needed for Service ServiceDisassembly TI8173b Cutaway View Part No Gun Shown Diffuser Seat Replacement ReassemblyAA RAC Assembly included with Model 288053 only PartsParts Part Ref. No. No Description QtyDescription Qty North America and International ManifoldPart No. Description Qty Manifold with Bottom Fluid PortsSide Fluid Ports and Fan Adjustment Valve Part No C343RING, Ptfe 311052E Typical Air Application Tip Used With Consumption AAP Series Tip and Air Cap Selection ChartsAAP Series Precision Spray Tips LTX Reverse-A-Clean RAC Spray Tips LTX Series RAC Tip Selection ChartsFor use with G40 RAC Housing WRX Wide RAC Spray Tips RAC Switch TipsFFT Fine Finish RAC Spray Tips Accessories Ultimate Gun Cleaning Kit 15C161 Grounding Clamp and Wire In-line Fluid FilterAir Cap Seal Kit Plastic Seat Repair KitDimensions Mounting Hole Layout Rear Port Manifold Gun with Rear Port ManifoldTechnical Data Triggering SpeedSound Data dBa Models 3/16 in. ball Cylinder Air Pressure Fluid PressureGraco Standard Warranty Graco Information