NOTE: Check all possible solutions before disassembling the pump.

Problem

Cause

Solution

 

 

 

Uneven spray pattern

Bead pressure too low

Increase pressure to bead tank, or

 

 

adjust bead pressure regulator

 

 

 

Spray gun will not stop spraying

Gun needle binding

Clean, repair

 

 

 

 

Obstructed or worn needle seat

Clean or replace

 

 

 

Spray gun will not spray

Bead line clogged

Clear

 

 

 

 

Bead valve closed

Open

 

 

 

 

Clogged orifice or needle seat

Clean

 

 

 

 

No trigger or actuator air pressure

Check, clean air lines

 

 

 

 

Wet beads

Drain beads from tank and replace

 

 

with dry beads.

 

 

 

8308612

Image 8
Contents INSTRUCTIONS-PARTS LIST 308612Model 238338, Series A Rev. DTable of Contents SymbolsWarning Symbol Caution SymbolEQUIPMENT MISUSE HAZARD Installation Mount ValveConnect the Air Lines GroundingPressure Relief Procedure AdjustmentsOperation Application DataSpeed Bead Coverage in Pounds Per Gallon kg/LTank BeadMaintenance ServiceClean Dispensing Valve and System Daily 1. Follow Pressure Relief Procedure on pageTroubleshooting ProblemSolution Cause308612 05950A PartsModel Accessories Valve Seat & O-ring KitsIncludes O-ring Wide Bead Deflector KitTechnical Data Graco WarrantyADDITIONAL WARRANTY COVERAGE Graco Phone Number