Pressure Relief Procedure

4. Verify the Trigger lock is engaged.

To relieve fluid and air pressures:

1.Push down Yellow slide valve, P/N 21402-00 to bleed off air to system.

2.Open P/N 21228-00 on catalyst pump to recirculation position.

3.Open P/N 21192-00 on bottom of material pump.

Daily Maintenance

It is recommended that the following service be per- formed on a daily basis.

1.Remove gear cover, p/n: 23756-00, and inspect valves to see if there is any leakage on the top or bottom side of the valves. If there is leakage, with pressure relieved, tighten packing nut, p/n: 23764-00 1/8 to 1/4 turn until leak stops. Verify that there is no leakage.

2.Maintain a reasonable stock level of “wear” items such as Packings, Seals and O-Rings

3.If dispense gun is leak tested, be sure to dry gun thoroughly.

4.Never leave dispense gun immersed in any liquid.

14

GC-1387H

Image 14
Contents Formula Gun Contents Fire and Explosion Hazard Skin Injection Hazard Spraying and Lamination Operations Methyl Ethyl Ketone Peroxide MekpPolyester Resins and Gel-Coats Grounding Set-Up Hose AttachmentOvernight Shut Down Procedure Repair Kits PartsFormula Dispense Gun Part Description Number Part Description NumberFormula Dispense Gun 72123-40 Part Description Qty GC-1387H Pressure Relief Procedure Daily MaintenanceMaintenance Parts Replacement Procedure Formula GunRing Chart Material Valve Assembly Procedure Width Output lbs AccessoriesMin Max Part Orifice Number LPA2-147-6225 062 6240 6250 6265 7240 072 7250 7840 078 Small Diameter Airless Or Non Atomized Material Tip Internal Mix Gel Screw-On AAC Gun Head Kit Assy Part DescriptionDual AIR Assist Body High Volume / High Filled Resin Part Description Number Technical Data Category DataGC-1387H Graco Ohio Standard Warranty Graco Ohio Information