Graco Inc GC-1387J important safety instructions Overnight Shut Down Procedure

Page 8

Set-Up

Overnight Shut Down Procedure

The following steps should be followed for overnight shutdown:

1.The yellow air valve located where the air enters the machine should be pushed to the “OFF” (closed) position. To do this simply push on the lever protruding out the side of the valve. This will also cause all the system air to bleed out of the system in a matter of a few seconds thus making the system incapable of operating.

Step 2 is a precautionary step and should be followed whenever the emergency stop valve is activated to the stop mode. Failure to do so will damage regulators and components when reactivating to the ON position.

2.Turn all system regulators to OFF (counter- clockwise) position.

Verify that the Catalyst Pressure Relief Line and the Resin Return Line are secured before relieving

catalyst and resin fluid pressure.

3.Catalyst pressure in the Slave Pump can be eliminated by rotating the yellow valve handle on the Slave Pump 90 degrees to the “ON” position.

The “ON” position the valve handle is parallel (in line) with the valve body .

The “OFF” position the valve handle is perpendicular (across) the valve body.

4.Resin pressure can be eliminated by rotating the yellow handled valve on the bottom of the fluid filter 90 degrees. Place a container under the bottom of the valve to catch any resin that is ejected from the valve.

8

GC-1387H

Image 8
Contents Formula Gun Contents Fire and Explosion Hazard Skin Injection Hazard Spraying and Lamination Operations Methyl Ethyl Ketone Peroxide MekpPolyester Resins and Gel-Coats Grounding Set-Up Hose AttachmentOvernight Shut Down Procedure Parts Formula Dispense Gun Part Description NumberRepair Kits Part Description NumberFormula Dispense Gun 72123-40 Part Description Qty GC-1387H Pressure Relief Procedure Daily MaintenanceMaintenance Parts Replacement Procedure Formula GunRing Chart Material Valve Assembly Procedure Width Output lbs AccessoriesMin Max Part Orifice Number LPA2-147-6225 062 6240 6250 6265 7240 072 7250 7840 078 Small Diameter Airless Or Non Atomized Material Tip Internal Mix Gel Screw-On AAC Gun Head Kit Assy Part DescriptionDual AIR Assist Body High Volume / High Filled Resin Part Description Number Technical Data Category DataGC-1387H Graco Ohio Standard Warranty Graco Ohio Information