Carrier 38HDR Electrical Data, 38QRR Electrical Data, 40QAC/QAQ Electrical Data

Page 14

40QAC/38HDR -- 40QAQ/38QRR

ELECTRICAL DATA

Table 10 – 38HDR Electrical Data

38HDR

V---PH ---

Hz

VOLTAGE RANGE*

COMPRESSOR

OUTDOOR FAN MOTOR

MIN CKT

FUSE/HACR

UNIT SIZE

Min

Max

RLA

LRA

FLA

NEC Hp

kW Out

AMPS

BKR AMPS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

018

208/230---

1---

60

187

253

9.0

48.0

0.8

0.125

0.09

12.1

20

 

 

 

 

 

 

 

 

 

 

 

 

 

024

208/230---

1---

60

187

253

13.5

58.3

0.8

0.125

0.09

17.7

25

 

 

 

 

 

 

 

 

 

 

 

 

 

030

208/230---

1---

60

187

253

14.1

73.0

1.5

0.25

0.19

19.1

30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

208/230---

1---

60

187

253

14.1

77.0

1.5

0.25

0.19

19.1

30

 

 

 

 

 

 

 

 

 

 

 

 

 

036

208/230---

3---

60

187

253

9.2

71.0

1.5

0.25

0.19

13.0

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

460---

3---

60

414

506

5.6

38.0

0.8

0.25

0.19

7.9

15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

208/230---

1---

60

187

253

19.9

109.0

1.5

0.25

0.19

26.4

40

 

 

 

 

 

 

 

 

 

 

 

 

 

048

208/230---

3---

60

187

253

13.1

83.1

1.5

0.25

0.19

17.9

25

 

460---

3---

60

414

506

6.1

41.0

0.8

0.25

0.19

8.9

15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

208/230---

1---

60

187

253

26.4

134.0

1.5

0.25

0.19

34.5

60

 

 

 

 

 

 

 

 

 

 

 

 

 

060

208/230---

3---

60

187

253

15.0

110.0

1.5

0.25

0.19

21.5

30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

460---

3---

60

414

506

7.8

52.0

0.8

0.25

0.19

10.6

15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 11 – 38QRR Electrical Data

38QRR

 

 

 

 

VOLTAGE

COMPRESSOR

OUTDOOR FAN MOTOR

MIN CKT

FUSE/HACR BKR

V---PH ---

Hz

RANGE*

 

 

 

 

 

UNIT SIZE

RLA

LRA

FLA

NEC Hp

kw Out

AMPS

AMPS

 

 

 

 

 

Min

Max

 

 

 

 

 

 

 

 

 

 

 

 

 

 

018

208/230---

1---

60

187

253

9.0

48.0

0.8

0.125

0.09

12.1

20

 

 

 

 

 

 

 

 

 

 

 

 

 

024

208/230---

1---

60

187

253

14.4

58.3

0.8

0.125

0.09

18.8

30

 

 

 

 

 

 

 

 

 

 

 

 

 

030

208/230---

1---

60

187

253

12.8

64.0

1.5

0.25

0.19

17.5

30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

208/230---

1---

60

187

253

15.5

77.0

1.5

0.25

0.19

20.9

30

 

 

 

 

 

 

 

 

 

 

 

 

 

036

208/230---

3---

60

187

253

10.1

71.0

1.5

0.25

0.19

14.1

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

460---

3---

60

414

506

5.6

38.0

0.8

0.25

0.19

7.9

15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

208/230---

1---

60

187

253

26.5

117.0

1.5

0.25

0.19

34.6

50

 

 

 

 

 

 

 

 

 

 

 

 

 

048

208/230---

3---

60

187

253

16.7

83.1

1.5

0.25

0.19

22.4

30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

460---

3---

60

414

506

7.3

41.0

0.8

0.25

0.19

10.0

15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

208/230---

1---

60

187

253

26.4

134.0

1.5

0.25

0.19

34.5

60

 

 

 

 

 

 

 

 

 

 

 

 

 

060

208/230---

3---

60

187

253

17.7

110.0

1.5

0.25

0.19

23.6

40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

460---

3---

60

414

506

7.8

52.0

0.8

0.25

0.19

10.6

15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 12 – 40QAC/QAQ Electrical Data

UNIT

 

VOLTAGE

VOLTAGE

FAN

HEATER

 

POWER

 

MINIMUM

 

RANGE*

 

 

 

 

 

WIRE SIZE

 

 

V---Ph---60 Hz

 

 

FLA

 

 

 

 

 

(AWG)

 

 

MIN.

MAX.

kW

FLA

MCA

MOCP

FLA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40QAC024---

3

208/230---

1

187

253

0.50

0.63

15.0

0.50

14

 

 

 

 

 

 

 

 

 

 

 

 

 

40QAC036---

3

208/230---

1

187

253

1.30

1.60

15.0

1.30

14

 

 

 

 

 

 

 

 

 

 

 

 

 

40QAC048---

3

208/230---

1

187

253

1.60{

2.00

15.0

1.60

14

 

 

 

 

 

 

 

 

 

 

 

 

 

40QAC060---

3

208/230---

1

187

253

2.60}

3.30

15.0

2.60

14

 

 

 

 

 

 

 

 

 

 

 

 

 

40QAQ024---

3

208/230---

1

187

253

0.50

2.00

8.66

9.29

15.0

11.29

14

 

 

 

 

 

 

 

 

 

 

 

 

 

40QAQ036---

3

208/230---

1

187

253

1.30

3.00

13.00

17.70

20.0

14.30

14

 

 

 

 

 

 

 

 

 

 

 

 

 

40QAQ048---

3

208/230---

1

187

253

1.60{

4.00

17.40

23.80

25.0

19.00

12

 

 

 

 

 

 

 

 

 

 

 

 

 

40QAQ060---

3

208/230---

1

187

253

2.60{

5.00

21.70

28.70

30.0

24.30

10

 

 

 

 

 

 

 

 

 

 

 

 

 

LEGEND

NOTES

FLA

--- Full Load Amps

*

Permissible limits of the voltage range at which the unit will operate

LRA

--- Locked Rotor Amps

 

satisfactorily

MCA

--- Minimum Circuit Amps

{ One fan is 1.1 amps, the second fan is 0.5 amps.

RLA

--- Rated Load Amps

}

Two fans each operating at 1.3 amps.

14

Image 14
Contents 38HDR, QRR Unit Safety Considerations40QAC, QAQ Unit Size Dimensions IndoorUnit 38HDR Outdoor Unit Dimensions English 38HDR Outdoor Unit Dimensions SI 38QRR Outdoor Unit Dimensions English 38QRR Outdoor Unit Dimensions SI Parts List System RequirementsPower and Connecting Cables Field Supplied User Interface Finished Goods AccessoryInstallation Fan Coil Unit Hanging Dimensions Mounting Unit on Wall Mounting on GroundMounting on Roof Connection at Outdoor Unit Complete Outdoor Power and Control WiringComplete Outdoor Refrigerant Piping Connec- tions Power Wiring Line Power Connections40QAC/QAQ Electrical Data 38HDR Electrical Data38QRR Electrical Data 38HDR and 40QAC Cooling System Wiring Diagram 38QRR and 40QAQ Heat Pump System Wiring Diagram Complete Indoor Piping Connect Condensate Drain LineInstall Thermostat Complete Control WiringComplete Power Connection To Indoor Unit Reassemble Indoor Unit Using Vacuum PumpSTART-UP Preliminary ChecksTo Start the Unit Manifold Deep Vacuum MethodCleaning and Maintenance Operating SequenceTo clean or replace drain pan ServiceTo clean the outdoor coil Cleaning and Maintenance ScheduleTroubleshooting TroubleshootingBefore Calling for Service Problem Cause Typical SolutionTroubleshooting the Heating Cycle Troubleshooting the Cooling Cycle 2SI

40QAC specifications

The Carrier 40QAC is a standout product in the realm of commercial air conditioning systems. This air-cooled chiller is designed to meet a variety of cooling needs while ensuring energy efficiency and reliability. One of the most notable features of the 40QAC is its advanced scroll compressor technology, which is engineered to provide consistent performance with reduced noise levels. This makes it an ideal choice for applications where minimizing sound pollution is crucial, such as in urban settings or near sensitive environments.

In terms of energy efficiency, the 40QAC boasts impressive ratings, with a high coefficient of performance (COP) that helps to lower operational costs and reduce environmental impact. Its design integrates various energy-saving features, including variable speed fans and a robust control system that optimizes performance based on real-time demand. This adaptability allows the chiller to maintain comfort levels while consuming less energy than traditional models.

The 40QAC is equipped with a microprocessor-based control system that simplifies operation and enhances user experience. This intelligent control interface allows operators to monitor performance metrics, adjust settings, and troubleshoot any issues remotely, increasing overall system reliability. The system is also designed to be compatible with building management systems, which facilitates seamless integration into existing infrastructure.

Another prominent characteristic of the Carrier 40QAC is its robust construction. Built with high-quality materials, it offers excellent durability and longevity, even in challenging environmental conditions. The unit also incorporates features to streamline maintenance, such as accessible component layout and easy-to-remove panels, ensuring that downtime for servicing is minimized.

Safety is another critical aspect of the Carrier 40QAC’s design. It’s engineered with numerous safety protocols to protect against overheating, overpressure, and other potential hazards, guaranteeing both system integrity and peace of mind for operators.

Overall, the Carrier 40QAC is a versatile and efficient solution for commercial cooling needs. With its technological advancements, energy-saving features, and robust design, it stands out as a reliable choice for businesses looking to balance performance with sustainability. The 40QAC not only promises efficient cooling but does so while aligning with the growing demand for eco-friendly solutions in today's marketplace.