Carrier 40QAC installation instructions 38QRR Outdoor Unit Dimensions SI

Page 6

40QAC/38HDR -- 40QAQ/38QRR

X = YES

O = NO

AIR

AIR

6

B

A

1. REQUIREDCLEARANCES: WITH COIL FACINGWALL; ALLOW 152.4MIN CLEARANCE ON COIL SIDE ANDCOIL END AND 914.4 MIN CLEARANCE ON COMPRESSOR END AND FAN SIDE. WITH FAN FACING WALL;ALLOW 203.2 MIN CLEARANCE ON FAN SIDE AND COIL END AND914.4 MIN CLEARANCE ON COMPRESSOR END AND COIL SIDE. WITH MULTI UNIT APPLICATION;

ARRANGE UNITS SO DISCHARGE OF ONEDOES NOT ENTER INLET OF ANOTHER.

2. MINIMUM OUTDOOR OPERATING AMBIENT IN COOLING

MODE IS 12.8

C, MAX. 51.7

C.

3. SERIES DESIGNATION IS THE 13TH POSITION OF THE UNIT MODEL NUMBER.

4. CENTER OF GRAVITY

5. ALL DIMENSIONS ARE IN "MM" UNLESS NOTED.

 

FIELD POWER SUPPLY CONN.

 

HOLE SIZES PROVIDED:

JUNCTION BOX FOR

22.22 - 12.70 TRADE

30.16 - 19.05 TRADE

POWER SUPLLY AND

34.92 - 25.40 TRADE

CONTROL CONNECTIONS

36.5

 

FIELD CONTROL SUPPLY

 

 

WIRE ENTRY

 

 

22.22 HOLE W/GROMMET

 

 

 

38.1

M VAPOR LINE CONN.

 

H

 

G

FEMALE SWEAT CONN.

 

 

 

 

L

 

 

 

203.2

9.53 LIQUID LINE

25.4

114.3

MALE FLARE CONN.

 

 

Fig. 5 - 38QRR Outdoor Unit Dimensions - SI

Image 6
Contents Safety Considerations 40QAC, QAQ Unit38HDR, QRR Unit Dimensions Indoor UnitSize 38HDR Outdoor Unit Dimensions English 38HDR Outdoor Unit Dimensions SI 38QRR Outdoor Unit Dimensions English 38QRR Outdoor Unit Dimensions SI Parts List System RequirementsPower and Connecting Cables Field Supplied User Interface Finished Goods AccessoryInstallation Fan Coil Unit Hanging Dimensions Mounting on Ground Mounting on RoofMounting Unit on Wall Complete Outdoor Power and Control Wiring Complete Outdoor Refrigerant Piping Connec- tionsConnection at Outdoor Unit Power Wiring Line Power Connections38HDR Electrical Data 38QRR Electrical Data40QAC/QAQ Electrical Data 38HDR and 40QAC Cooling System Wiring Diagram 38QRR and 40QAQ Heat Pump System Wiring Diagram Complete Indoor Piping Connect Condensate Drain LineComplete Control Wiring Complete Power Connection To Indoor UnitInstall Thermostat Reassemble Indoor Unit Using Vacuum PumpSTART-UP Preliminary ChecksTo Start the Unit Manifold Deep Vacuum MethodCleaning and Maintenance Operating SequenceTo clean or replace drain pan ServiceTo clean the outdoor coil Cleaning and Maintenance ScheduleTroubleshooting TroubleshootingBefore Calling for Service Problem Cause Typical SolutionTroubleshooting the Heating Cycle Troubleshooting the Cooling Cycle 2SI

40QAC specifications

The Carrier 40QAC is a standout product in the realm of commercial air conditioning systems. This air-cooled chiller is designed to meet a variety of cooling needs while ensuring energy efficiency and reliability. One of the most notable features of the 40QAC is its advanced scroll compressor technology, which is engineered to provide consistent performance with reduced noise levels. This makes it an ideal choice for applications where minimizing sound pollution is crucial, such as in urban settings or near sensitive environments.

In terms of energy efficiency, the 40QAC boasts impressive ratings, with a high coefficient of performance (COP) that helps to lower operational costs and reduce environmental impact. Its design integrates various energy-saving features, including variable speed fans and a robust control system that optimizes performance based on real-time demand. This adaptability allows the chiller to maintain comfort levels while consuming less energy than traditional models.

The 40QAC is equipped with a microprocessor-based control system that simplifies operation and enhances user experience. This intelligent control interface allows operators to monitor performance metrics, adjust settings, and troubleshoot any issues remotely, increasing overall system reliability. The system is also designed to be compatible with building management systems, which facilitates seamless integration into existing infrastructure.

Another prominent characteristic of the Carrier 40QAC is its robust construction. Built with high-quality materials, it offers excellent durability and longevity, even in challenging environmental conditions. The unit also incorporates features to streamline maintenance, such as accessible component layout and easy-to-remove panels, ensuring that downtime for servicing is minimized.

Safety is another critical aspect of the Carrier 40QAC’s design. It’s engineered with numerous safety protocols to protect against overheating, overpressure, and other potential hazards, guaranteeing both system integrity and peace of mind for operators.

Overall, the Carrier 40QAC is a versatile and efficient solution for commercial cooling needs. With its technological advancements, energy-saving features, and robust design, it stands out as a reliable choice for businesses looking to balance performance with sustainability. The 40QAC not only promises efficient cooling but does so while aligning with the growing demand for eco-friendly solutions in today's marketplace.