MAINTENANCE
General Maintenance
Checking & Replacing the Needle
Needle wear is expexcted and inspection during Cleaning will ensure the continued top- performance of your
Step 1.
Step 2.
Unscrew the FAN ADJUSTING SCREW (#28) and remove the SPRING (#27).
Using a pair of pliers or other suitable device, carefully pull and twist the NEEDLE ASSEMBLY (#24”S”) until it has been removed.
NOTE (Step 1)Before unscrewing the
ADJUSTMENT SCREW, place a mark on the ADJUSTMENT SCREW where it meets the GUN HOUSING (#13). This will make re- adjusting the gun, after maintenance, easier.
Step 3.
Step 4.
Step 5.
Step 6.
Purchase an identical replacement NEEDLE ASSEMBLY from Harbor Freight Tools.
By hand, carefully insert the needle into the GUN HOUSING (#5) and push until the tip has exited the hole in the AIR CAP (#1).
Place the SPRING over the NEEDLE ASSEMBLY and insert it into the
SPRAYER HOUSING.
Replace the ADJUSTING SCREW and readjust its setting to the position it was in before removed (refer to Step 1).