I.C.T.C. Holdings Corporation B series owner manual Hydrapulse Membrane Test

Page 16

TROUBLESHOOTING

HYDRAPULSE MEMBRANE TEST

If your unit is disabled and you are unable to perform a pressure test, use the following procedures for determining the area to repair. This test will divide the two halves of the equipment (hydraulic from paint) and make identification of your solution easier to obtain. This test is commonly referred to as the "Hydrapulse Membrane Test"

The solution to almost all problems can be found in the paint side valves, due to the increased wear from contact with the abrasive paint/spray materials. Intake valve (ref# 16-28) and Outgo valve (ref#32) make up the paint valves. Refer to pages where exploded views of these valves are shown.

To eliminate the hydraulic side of the pump (piston / oil side of hydrapulse membrane) as a source of problems;

1.Remove the intake valve end cap (ref# 16) by removing the four cap screws (ref# 14). The intake valve assembly, (ref# 16-24), will generally come off as an entire assembly, requiring no further dismantling. If the ball guide (ref# 23) and ball stop (ref# 24), remain in the paint head, they can be pried free with a screwdriver.

2.Start unit.

3.Increase the pressure by turning the pressure control knob (ref# 71) clockwise to full pressure.

4.Put pressure on the center of the exposed hydrapulse membrane with the handle of a screwdriver or other blunt object.

NOTE: The hydrapulse membrane is located between the paint head (ref# 27) and the hydraulic head (ref# 51)

5.If you are:

-UNABLEto stop or alter the hydrapulse membrane's movement, then the hydraulic side is operating properly. The problem is located in the “Paint” pump. See troubleshooting guide for additional information.

-ABLEto stop or alter the hydrapulse membrane's movement, then the hydraulic pump is not operating properly. The problem is located in the “Hydraulic” pump. See troubleshooting guide for a d d i t i o n a l

information.

16

14

51

27

H.E.R.O. INDUSTRIES LTD.

15

1100MD OWNERS MANUAL - “B” VERSION

Image 16
Contents NEW For Hydrapulse B Version Starting with serial R.O. Warranty Table of Contents Important Safety Precautions Always AlwaysR.O. Airless Spray Painting Series Hydrapulse Intake AssemblyOperating Instructions Setting UP to Spray Flushing the Unit AT Shutdown Or Color Change Special Storage InstructionsSpecial Notes General Maintenance Instructions Airless Spray Painting Suggestions and Technique For Excellent RESULTS, Read and Practice These TechniquesPoor Good Tailing Good Pattern Fog, Overspray Spray TIP Selection TIP Size For ApplicationTroubleshooting Hydraulic Intake Valve REF# 59 Pressure Test Hydrapulse Membrane Test Situation Sprayer does not Prime with Paint Puddle of OIL Appearing Under Sprayer During Operation Spray Pattern is Spotty or Uneven Hydrapulse Membrane Replacement REF# 46 KITReplacement of Intake Seat REF # Outgo Valve REF# Tools Required -1 wrenchPiston Repairs REF#Page Pressure Control Valve Accessories Parts List Parts ListIntake Parts Outgo Parts 45A TANK, Complete. Includes Ref# Drive Parts 116 PW-4080 Foot PAD, Includes Ref# 1100MD Schematic Partsschematics Authorized Sales and Service Centers U.S.A Authorized Sales and Service CENTERS- U.S.A Southern CaliforniaNEW York Rhode Island R.O. Industries 2719 Lake City WAY BURNABY, B.C Canada