Hobart Welding Products OM-2210 manual Installation, Specifications For CE Model

Page 15

SECTION 3 – INSTALLATION

3-1. Specifications For Units Connected to a 20 Ampere, 115 Volt Circuit or a 10 Ampere, 230 Volt Circuit

 

Amperes Input at

 

 

 

 

Rated

 

 

Rated Output,

 

 

 

Plasma

 

 

 

 

 

Cutting

 

 

60 Hz, Single-Phase

 

 

 

 

 

115 V

230 V

Plasma

Gas Flow/

Capacity

Max

 

 

 

Rated Output

115 V

230 V

KVA/KW

KVA/KW

Gas

Pressure

at 10 IPM

OCV

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

115 VAC

 

 

 

 

 

 

Air Or

4.5 CFM

Input: 1/4 in

 

21 A at 88 Volts DC At

25.3 max;

12.6 max;

2.9 KVA

2.9 KVA

(129 L/min)

(6 mm);

265 Volts

Nitrogen

35% Duty Cycle

15 eff

7.5 eff

2.2 KW

2.2 KW

At 60 PSI

230 VAC

DC

Only

 

 

 

 

 

(414 kPa)

Input: 5/16 in

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(8 mm)

 

 

 

 

 

 

 

 

 

 

3-2. Specifications For Units Connected to a 30 Ampere, 115 Volt Circuit or a 15 Ampere, 230 Volt Circuit

NOTE

If the unit is operated from a 30 ampere, 115 volt circuit or a 15 ampere, 230 volt circuit, a different input power plug must be installed on the power cord. See Section 3-9 for instructions.

 

Amperes Input at

 

 

 

 

Rated

 

 

Rated Output,

 

 

 

Plasma

 

 

 

 

 

Cutting

 

 

60 Hz, Single-Phase

 

 

 

 

 

115 V

230 V

Plasma

Gas Flow/

Capacity

Max

 

 

 

Rated Output

115 V

230 V

KVA/KW

KVA/KW

Gas

Pressure

at 10 IPM

OCV

 

 

 

 

 

 

 

 

 

27 A at 91 Volts DC At

33.6 max;

16.8 max;

3.8 KVA

3.8 KVA

 

 

115 VAC

 

35% Duty Cycle

19.9 eff

9.9 eff

3.1 KW

3.1 KW

 

 

 

 

 

 

 

 

Air Or

4.5 CFM

Input: 1/4 in

 

21 A at 88 Volts DC At

25.3 max;

12.6 max;

2.9 KVA

2.9 KVA

 

(129 L/min)

(6 mm);

265 Volts

Nitrogen

60% Duty Cycle

19.6 eff

9.8 eff

2.2 KW

2.2 KW

At 60 PSI

230 VAC

DC

Only

 

 

 

 

 

(414 kPa)

Input: 5/16 in

 

17 A at 87 Volts DC At

20.9 max;

10.5 max;

2.4 KVA

2.4 KVA

 

 

 

 

(8 mm)

 

100% Duty Cycle

20.9 eff

10.5 eff

1.8 KW

1.8 KW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3-3. Specifications For CE Model

 

Amperes Input at

 

 

 

 

 

 

 

Rated Output,

 

 

 

 

 

 

 

50 Hz,

 

 

 

Plasma

 

 

 

Single-Phase

 

 

 

 

 

 

 

 

 

 

Plasma

Gas Flow/

Max

IP

Rated Output

115 V

230 V

KVA

KW

Gas

Pressure

OCV

Rating

 

 

 

 

 

 

 

 

 

115 VAC Input:

 

 

 

 

 

 

 

 

20 A @ 89 Volts DC

 

 

115 VAC

115 VAC

 

 

 

 

(20 A Input Circuit);

 

 

 

 

 

 

 

 

Input: 3.1

Input: 2.4

Air Or

4.5 CFM

 

 

25 A @ 89 Volts DC

 

 

 

 

26

17

(0.05*)

(0.04*)

(129 L/min)

 

 

(30 A Input Circuit);

Nitrogen

265 Volts DC

23

(0.4*)

(0.2*)

230 VAC

230 VAC

At 60 PSI

230 VAC Input:

Only

 

 

 

 

Input: 4.0

Input: 3.1

(414 kPa)

 

 

25 A @ 89 Volts DC;

 

 

 

 

 

 

 

(0.05*)

(0.04*)

 

 

 

 

35% Duty Cycle In All

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cases

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*While idling

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OM-2210 Page 11

Image 15
Contents OM-2210 ProcessesDescription From Hobart to You Table of Contents Standards DirectivesCutting can cause fire or explosion Symbol UsageMarks a special safety message Plasma Arc Cutting HazardsFumes and Gases can be hazardous Flying Sparks can cause injuryARC Rays can burn eyes and skin Noise can damage hearingOveruse can cause Overheating HOT Parts can cause severe burnsMoving Parts can cause injury Flying Metal can injure eyesPrincipal Safety Standards EMF InformationAbout Pacemakers Identifie un message de sé curité particulier Signification des symbolesLE Coupage pré sente un risque de feu ou d’explosion UNE DÉ Charge É Lectrique peut entraîner la mortLES Bouteilles peuvent exploser si elles sont endommagé es LE Bruit peut endommager l’ouïeLES Fumé ES ET LES GAZ peuvent ê tre dangereux LE Plasma D’ARC peut entraîner des blessuresPrincipales normes de sé curité Consignes relatives aux stimulateurs cardiaques Information sur les champs é lectromagné tiquesDefinitions I1eff Symbols And DefinitionsManufacturer’s Rating Label For CE Products I1maxSpecifications For CE Model InstallationOverheating Exceeding duty cycle can damage unit and void warrantyDuty Cycle And Overheating For Non-CE Model Duty Cycle And Overheating For CE ModelSelecting a Location Dimensions And WeightConnecting Work Clamp And Gas/Air Supply Rear Of Unit Installing Alternative PlugSetting Gas/Air Pressure OperationControls Cutting Speed Sequence Of Operation Example Of Cutting OperationTrigger is pressed Months Maintenance & TroubleshootingChecking Torch Shield Cup Shutdown System Ways turn Off power when changing or checking consumablesTorch And Work Cable Connections Torch ConnectionsWork Cable Connections Trouble Remedy TroubleshootingCircuit Diagram For Power Source Electrical DiagramMain Assembly Parts ListDia Part Mkgs Description Quantity +181 Support ServiceHobart Welding Products Contact your Distributor for