SECTION 4 − OPERATION
4-1. Controls
2
1
| . Spool Gun | On/Off | switch in | ||
|
| Millermatic | 185 | Hobart | |
|
| IronMan 210 or IronMan 250 | |||
|
| must be in On position for spool | |||
|
| gun operation (see Field Kit | |||
|
| 207 642 instructions). | |||
| 1 | Shielding Gas Cylinder | |||
| For shielding gas connections, see | ||||
| welding | power | source | Owner’s | |
| Manual. |
|
|
| |
| 2 | Valve |
|
| |
| Open valve on cylinder just before | ||||
| welding. |
|
| ||
| 3 | Trigger |
|
| |
| Press trigger to energize welding | ||||
| power | source | contactor, start | ||
| shielding gas flow, and begin wire | ||||
| feed. |
|
|
| |
3 | Wire feed speed is controlled by | ||||
| welding power source Wire Speed | ||||
| control | (see appropriate welding | |||
| power source Owner’s Manual). |
Close valve on cylinder when finished welding.
sb5.1* 6/92 −
SECTION 5 − MAINTENANCE & TROUBLESHOOTING
5-1. Routine Maintenance
|
|
| ! Disconnect power | . Maintain more often |
|
|
| before maintaining. | during severe conditions. |
n = Check | Z = Change | ~ = Clean | l = Replace | Reference |
* To be done by Factory Authorized Service Agent |
|
|
Every l Unreadable Labels | ~ Weld Terminals | l Damaged Gas Hose | nl Weld Cables |
3 |
|
|
|
Months |
|
|
|
nl Cords | nl Gun Cables | |
Every |
| |
6 | OR | |
Months | ||
|
~Drive Rolls
~Inside Unit