24ANA

Infinityt Series Air Conditioners with Puronr Refrigerant

2 to 5 Nominal Tons (Sizes 24 to 60)

Installation Instructions

NOTE: Read the entire instruction manual before starting the installation.

Unless otherwise noted, information in these installation instructions pertain to both 24ANA1 and 24ANA7 series units. Information that is unique to the 24ANA1 series will be identified as such; likewise information that is unique to the 24ANA7 series will also be identified.

SAFETY CONSIDERATIONS

Improper installation, adjustment, alteration, service, maintenance, or use can cause explosion, fire, electrical shock, or other conditions which may cause death, personal injury, or property damage. Consult a qualified installer, service agency, or your distributor or branch for information or assistance. The qualified installer or agency must use factory-authorized kits or accessories when modifying this product. Refer to the individual instructions packaged with the kits or accessories when installing.

Follow all safety codes. Wear safety glasses, protective clothing, and work gloves. Use quenching cloth for brazing operations. Have fire extinguisher available. Read these instructions thoroughly and follow all warnings or cautions included in literature and attached to the unit. Consult local building codes and current editions of the National Electrical Code (NEC) NFPA 70. In Canada, refer to current editions of the Canadian electrical code CSA 22.1.

Recognize safety information. This is the safety-alert symbol ! . When you see this symbol on the unit and in instructions or manuals, be alert to the potential for personal injury.

Understand these signal words; DANGER, WARNING, and CAUTION. These words are used with the safety-alert symbol. DANGER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies hazards which could result in personal injury or death. CAUTION is used to identify unsafe practices which may result in minor personal injury or product and property damage. NOTE is used to highlight suggestions which will result in enhanced installation, reliability, or operation.

Indoor Thermostat Control Options

Model

Infinity

Standard 2--- stage

Control

Thermostat

 

 

 

 

24ANA7

Yes

Yes

 

 

 

24ANA1

Yes

Yes*

 

 

 

* Units containing circuit board HK38EA015 or newer.

!WARNING

ELECTRICAL SHOCK HAZARD

Failure to follow this warning could result in personal injury or death.

Before installing, modifying, or servicing system, main electrical disconnect switch must be in the OFF position. There may be more than 1 disconnect switch. Lock out and tag switch with a suitable warning label.

!WARNING

UNIT OPERATION AND SAFETY HAZARD

Failure to follow this warning could result in personal injury, death and/or equipment damage.

Puron refrigerant systems operate at higher pressures than standard R-22 systems. Do not use R-22 service equipment or components on Puron equipment.

!CAUTION

CUT HAZARD

Failure to follow this caution may result in personal injury.

Sheet metal parts may have sharp edges or burrs. Use care and wear appropriate protective clothing and gloves when handling parts.

Image 1
Contents Unit Operation and Safety Hazard Safety ConsiderationsIndoor Thermostat Control Options Electrical Shock HazardInstallation Installation RecommendationsInstall on a Solid, Level Mounting Pad Check Equipment and Job SiteMake Piping Connections Operating AmbientOutdoor Unit Connected to Factory Approved Indoor Unit Personal Injury and Environmental HazardAccessory Usage Install Liquid-Line Filter Drier IndoorRefrigerant Tubing Connection Outdoor Sweat ConnectionMake Electrical Connections Install AccessoriesCompressor Crankcase Heater Make Airflow Selections START-UPEnvironmental Hazard System Functions And Sequence Of Operation Compressor Operation on 24ANA1 Models Time DelaysCrankcase Heater Operation Outdoor Fan Motor OperationCheck Charge TroubleshootingUnloader Test Procedure 230V Line Power Disconnect DetectionCompressor Voltage Sensing Contactor Shorted DetectionStage Control Failed Thermistor Default OperationField Connections Stage CompressorFinal Checks Care and MaintenanceStatus Codes TroubleshootingExample Volt Factory Wiring Puronr R-410A Refrigerant Quick Reference Guide Catalog No 24ANA---6SI