.A complete Parts List is available at www.HobartWelders.com
SECTION 5 − OPERATION
5-1. Controls
2
1
3
4
230
1 Power Switch
The cooling fan will run for a few seconds after the power switch is placed in the OFF position in order to discharge internal circuitry.
2 Power Light
Use light to tell if unit is energized and ready to operate. Light blinks if input power is not within specified range .
3 Cup Light | 4 Temp Light |
Light comes on if cup is removed from torch. | Light comes on if unit overheats. |
Once cup is reinstalled on torch, unit power |
|
must be turned off and back on again. |
|
5-2. Recommended Cutting Speed For Material Thickness
Material | Material Thickness |
| Recommended Cut Speed | ||
|
|
|
|
| |
| inches |
| mm | ipm | mm/min |
|
|
|
|
|
|
| 18 ga. |
| 1.0 | 22 | 558 |
|
|
|
|
|
|
Mild Steel | 16 ga. |
| 1.3 | 20 | 508 |
|
|
|
|
| |
14 ga. |
| 1.6 | 18 | 457 | |
|
| ||||
|
|
|
|
|
|
| 1/8 |
| 3.2 | 10 | 254 |
|
|
|
|
|
|
| 1/4 |
| 6.4 | 3 | 76 |
|
|
|
|
|
|
Aluminum and Stainless Steel cut speeds at these thicknesses may be reduced by as much as 30%.