Parker Products WCS-SIF-01 manual Installing Weld Block with Existing Equipment

Page 4

WCS-SIF-01

Training & Maintenance Manual

Installation & Setup Instructions

Installation – Air and Electrical

A. Installing Weld Block with Existing Equipment

1.Shut off air supply to weld gun and turn power off to cell.

2.Disconnect air hoses from existing weld block ports. This will vary depending on weld gun type, and whether the existing weld block is single or dual pressure.

Note: If the current weld block is mounted directly to the cylinder, then only the inlet port hoses will be disconnected.

3.Disconnect solenoid connectors from valves. Be sure to note which connectors are being used for pre-stroke (retract) valves and weld stroke valves.

4.Remove current weld block from gun.

B.Installing Weld Block on New Equipment

5.Mount weld block spotwelding system to robot using (4) M8 screws and torque to 130 to 145 in. lbs (14.7 to 16.4 Nm).

6.Connect all air hoses to weld block (see schematic on pages 2 or 3).

Note: An additional air hose may be necessary for the inlet, since this unit is dual pressure. If so, connect the already existing hose to the Pw port (pressure weld).

This hose should be supplying scheduled pressures from a proportional regulator. Connect the additional hose before the proportional regulator using a T-fitting so that full line pressure is being used. This hose should be connected to the Pr port (pressure retract).

8.Turn air supply and power on.

9.Check for air leaks. The weld cylinder should be in the home position (completely open). If not, check that all air hoses are connected to the correct ports. Verify that all solenoids are de-energized, and valve overrides are unactuated. Once this is done, verify the function of the weld block, by actuating the weld block valves using the manual overrides. Press and hold the retract (pre-stroke) valve manual override. The weld cylinder should move to the weld stroke position. Press and hold the weld stroke valve manual override [still holding the retract (pre-stroke) override]. The weld cylinder should now close. Release the weld stroke override and the retract (pre-stroke) override. The weld cylinder will return to home position.

Note: The weld stroke portion of the cylinder will move slower than the pre-stroke. This is due to the regulated pressure being used, as well as the flow control.

Adjusting the speed of the cylinder will be covered in the Setup Instructions. Repeat this process, now energizing the solenoids. The cylinder should perform the same. If not, verify that the solenoid connectors are located on the proper valves. Once the unit has been properly installed, the following setup procedure can be used to ensure that the Parker weld system is used to its fullest potential.

7.Connect the solenoid cables to the proper valves. Connect an M12 sensor cable to the feedback sensor on the unit. The other end of this cable should be wired to the PLC controller.

Wiring

Refer to valve Instruction Sheet for proper wiring connections. Available at: www.parker.com/pneumatic (see B6 and ISO size 2 valves Installation and Service Instructions).

 

3 Ported Installation

Retract

Weld Stroke

(Pre-Stroke)

Connector(s)

Connector(s)

 

Exhaust

Weld

 

Return

 

High

Retract

Weld

Weld

Pressure

Extend

Extend

Pressure

Inlet

 

 

Inlet

4 Ported Installation

Retract

 

 

Weld Stroke

(Pre-Stroke)

 

 

Connector(s)

 

Connector(s)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High

Pressure

Inlet

Weld

Pressure

Inlet

Retract

Retract

Weld

Weld

Extend

Return

Return

Extend

Pneumatic

Parker Hannifin Corporation Pneumatic Division Richland, Michigan www.parker.com/pneumatics

Image 4
Contents WCS-SIF-01 General Operation Spotwelding Units 3 ported guns Ansi 3 Ported Cylinder OptionFront View Back ViewAnsi 2 Ported Cylinder Option Ansi 4 Ported Cylinder Option Proportional / quick dump valve that sensesInstalling Weld Block on New Equipment Installing Weld Block with Existing EquipmentWiring Ported Installation Installation & Setup Instructions How to Set the Flow Control ProperlyHow to Set the Feedback Sensor Properly Open ClosePneumatic System with Low Impact and Rapid Approach Control Model Selection Examples Model Number Index B6 Namur Valves 3 Ported GunsVoltage WP ISOSeries Retract ValveNPT BsppModel Number Index 5599-1 Auto Size 000Model Number Index 5599-2 Size Subbase Kits Manifold Kits Ordering Information Manifold and Subbase Kit Ordering CodeHow To Order Add-A-Fold Assemblies Add-A-Fold Assembly Model NumberExample Bspp G Number StationsOrdering Information Model Number Index Generation Components Replacement Components ISO 2 Weld Block Exploded ViewB6 Series Dimensions DH Series 3 Ported Guns Dimensions DP Series 2 and 4 Ported Guns Dimensions145 .75 Inches 16.31 19.3 WP ISO Size 2 Manifold Mountable Weld Block Troubleshooting Cylinder does not extend / retractOffer of Sale Parker Hannifin Corporation