Assembly
To assemble your machine:
1.Position the base plate upside down and mount the casters to the base plate using
(16)
Figure 5.
Figure 5. Mounting casters to base.
2.Set the collector body on top of the base plate so the intake portion is near the edge of the base plate and the bolt holes are aligned, as shown in Figure 6. Secure the collector body to the base plate with (4) 5⁄16"-18 x 1⁄2" flange bolts.
Collector Body
Flange Bolts
Figure 6. Mounting collector to base.
3.Insert the rubber gasket between the collec- tor and lower outlet flange, and secure using
(8)5⁄16"-18 x 1⁄2" flange bolts, as shown in
Figure 7.
Note: When connecting parts that have a gas- ket applied to the mounting surface, always tighten the fasteners in a diagonal and rota- tional manner to ensure the gasket does not become crimped and the seal compromised.