Note: When calculating static pressure loss to determine if multiple lines can be left open at the same time, only include the main line numbers once.

5.Compare the total static pressure loss for that line to the maximum static pressure loss found on the data sheet for your machine (located toward the front of this manual).

—If the CFM for your static pressure loss is above the requirement of the machine, then the line will most likely be successful. Congratulations! You've just designed your own dust system. Refer to Page 30 to start buying the components necessary to make your system a reality.

—If the CFM for your static pressure loss is below the requirement of the machine, then that line will not effectively collect the dust. You must then modify some of the factors in that line to reduce the static pressure loss. Some of the ways to do this include 1) installing larger duct, 2) reducing amount of flexible duct used, 3) increasing machine dust port size, 4) moving machine closer to dust collector to eliminate duct length, and

5)reducing 90˚ elbows or replacing them with 45˚ elbows.

System Grounding

Since plastic hose is abundant, relatively inex- pensive, easily assembled and air tight, it is a very popular material for conveying dust from woodworking machines to the dust collector. We recommend using flexible hose (flex-hose) to connect the woodworking machine to the dust collector. However, plastic flex-hose and plastic duct are an insulator, and dust particles moving against the walls of the plastic duct create a static electrical build up. This charge will build until it discharges to a ground. If a grounding medium is not available to prevent static electrical build up, the electrical charge will arc to the nearest grounded source. This electrical discharge may cause an explosion and subsequent fire inside the system.

To protect against static electrical build up inside a non-conducting duct, a bare copper wire should be placed inside the duct along its length and grounded to the dust collector. You must also confirm that the dust collector is continuously grounded through the electrical circuit to the elec- tric service panel.

If you connect the dust collector to more than one machine by way of a non-conducting branching duct system and blast gates, the system must still be grounded as mentioned above. We recom- mend inserting a continuous bare copper ground wire inside the entire duct system and attaching the wire to each grounded woodworking machine and dust collector.

Always guard against static electrical build up by grounding all dust collection lines.

-26-

Model G0562Z/ZP, G1030Z2/Z2P (Mfg. 11/11+)

Image 28
Contents Dust Collector G0562Z G1030Z2Ss ,EAD from Leadbased PAINTS Table of Contents Introduction Manual AccuracyContact Info Machine DescriptionIdentification Paddle SwitchFilter Bag Motor Dust Collectors Impeller Information Safety Safety Instructions for MachineryChildren & BYSTANDERS. @ZZe XaYgZc ZghWZXdbZVYhigVXidc#Additional Safety for Dust Collectors Power Supply AvailabilityFull-Load Current Rating Circuit InformationGrounding Requirements Extension CordsMinimum Gauge Size 14 AWG 50 ftSetup Needed for SetupUnpacking Description QtyInventory Inventory Item QtySite Considerations Assembly To assemble your dust collectorOutlet Canister Support Installing wide foam strip 13. G0562Z/G0562ZP onlyInstalled inlet Model G0562Z/ZP, G1030Z2/Z2P Mfg /11+ G1030Z2/G1030Z2P onlyConnecting Power Power ConnectionDisconnecting Power Test Run To test run the machineGeneral Duct Material Designing SystemMetal Duct Flexible Duct Plastic DuctSystem Design Decide Who Will DesignSketch Your Shop Layout Sketch a Basic Duct Layout Machine Approximate Determine Required CFM of Each Machine Machine Determining Main Line Duct Size Determining Branch Line Duct SizeTotal CFM Branch Line Size 400 500 600 700 800 900 1000Calculating Duct Resistance Duct Approximate DiaLoss Per Foot Fitting 90˚ 45˚ Dia Elbow WyeYSystem Grounding Plastic Blast Gate General OperationsMachine Storage Accessories Dust collection accessoriesMetal Duct Starter Kit Reducers & Adapters Metal BranchesMetal Elbows Maintenance Bag CleaningSchedule LubricationBags Emptying/ReplacingTo replace the collection bag Service TroubleshootingSymptom Possible Cause Possible Solution Motor & ElectricalDust Collector Operation Wiring Wiring Safety InstructionsShock HAZARD. Ldg`c\dclgc\iVihXdc XdbedcZcih#E699AHLI8= Wiring DiagramStart capacitor Model G0562Z/ZP, G1030Z2/Z2P Mfg /11+ G0562Z/G1030Z2 Main Breakdown PartsSee H5783 Parts Breakdown G0562Z/G1030Z2 Main Parts List DescriptionG0562ZP/G1030Z2P Main Breakdown G0562ZP/G1030Z2P Main Parts List Model G0562Z/ZP, G1030Z2/Z2P Mfg /11+ 10. 8dbbZcih EaVXZ HiVbe =ZgZ 99.$5342!, .# 0//88 %,,.!- 7! Warranty and Returns Order Hours a DAY