Trane RTUB 207-224, RTCA 108-216 manual General data Rtub

Page 7

General information

Table 1 - General data - RTUB

Unit size

 

207

208

210

211

212

214

Compressor

 

 

 

 

 

 

 

Type/quantity

 

 

 

Helical rotary/2

 

 

Nominal size

(tons)

35/35

40/40

50/50

60/50

60/60

70/70

Evaporator

 

 

 

 

 

 

 

Evaporator Model

 

EG 120

EG 120

EG 140

EG 170

EG 170

EG 200

Water Storage

(l)

105

105

365

220

220

200

Minimum Flow

(l/s)

4.5

4.5

6.0

7.0

7.0

9.0

Maximum Flow

(l/s)

13.4

13.4

18.0

21.0

21.0

25.0

Evaporator inlet diameter

(inches)

5

5

6

6

6

6

Evaporator outlet diameter

(inches)

5

5

6

6

6

6

Minimum Starting/

 

 

 

 

 

 

 

Operating Ambient

(°C)

 

 

 

5

 

 

Refrigerant

 

 

 

 

R134a

 

 

Number of Independent

 

 

 

 

 

 

 

Refrigerant Circuits

 

 

 

 

2

 

 

Percent Minimum Load

(%)

 

 

 

17

 

 

Refrigerant Charge

(kg)

26

26

40

40

40

40

Oil Charge

(l)

12

12

14

14

14

16

Operating Weight

(kg)

2130

2130

2845

2845

2845

3250

Shipping Weight

(kg)

1860

1860

2570

2570

2570

2975

Unit size

 

216

217

218

220

222

224

Compressor

 

 

 

 

 

 

 

Type/Quantity

 

 

 

Helical rotary/2

 

 

Nominal size

(tons)

70/85

85/85

100/85

100/100

120/100

120/120

Evaporator

 

 

 

 

 

 

 

Evaporator Model

 

EG 200

EG 200

EG 250

EG 250

EG 340

EG 340

Water Storage

(l)

200

200

415

415

560

560

Minimum Flow

(l/s)

9.0

9.0

11.0

11.0

14.0

14.0

Maximum Flow

(l/s)

25.0

25.0

33.0

33.0

43.0

43.0

Evaporator inlet diameter

(inches)

6

6

6

6

6

6

Evaporator outlet diameter

(inches)

6

6

6

6

6

6

Minimum Starting/

 

 

 

 

 

 

 

Operating Ambient

(°C)

 

 

 

5

 

 

Refrigerant

 

 

 

 

R134a

 

 

Number of Independent

 

 

 

 

 

 

 

Refrigerant Circuits

 

 

 

 

2

 

 

Percent Minimum Load

(%)

 

 

17

 

 

 

Refrigerant Charge

(kg)

40

40

46

46

50

50

Oil Charge

(l)

16

16

16

16

19

22

Operating Weight

(kg)

3250

3250

3880

4050

4480

4550

Shipping Weight

(kg)

2975

2975

3405

3575

3855

3925

RLC-SVX03A-E4

7

Image 7
Contents Installation Operation Maintenance Refrigerant Contents Operation General information Inspection ChecklistUnit Inspection Description of the Unit Loose Parts InventoryGeneral data Rtub General data Rtca Installation responsibilities InstallationStorage Isolation Special Lifting and Moving InstructionsFoundation Length Width Height ClearancesReleasing the Nitrogen Holding Charge DrainageWater Connections Rtub Water Pressure Gauges Flow Switch InstallationWater Treatment Water Pressure-Relief Valves Refrigerant Safety ValvesInstalling and connecting temperature sensors Extension of sensor power cableConnecting the Rtub with a remote air-cooled condenser Electrical connections performed by the installerDetail of positions of refrigerant sensors 5R56-1 and 5R6-2 Units on the same level Rtca or other manufacturers condenser below the Rtub Discharge line Pressure tests and leak detectionEquivalent pressure drops Size of the liquid lineVacuum pump connection Vacuum pumpingUnit Voltage Phasing Installation ChecklistOperation Pre-start checkoutOverheating Start-up ProceduresSystem Restart After Extended Shutdown Shutdown proceduresSubcooling Seasonal Unit Start-upOperation Maintenance For units without discharge valve option For units with the discharge valve optionChecking the separator oil level Some symptoms of a refrigerant under-charged unitSome symptoms of a refrigerant over-charged unit Some symptoms of an oil over- charged unitCharge Isolation in the high or low side of the system R134a Field-Charging ProcedureMeasuring the oil level Filter Replacement ProcedureOil Charging Procedure Lubrication SystemFactory initial Oil-Charging Procedure Field Oil-Charging ProcedureMaintenance Maintenance contract Safety recommendationsTraining