EXTENSION CORDS

Use proper extension cords. Make sure your extension cord is in good condition and is a 3-wire extension cord which has a 3-prong grounding type plug and a 3-hole receptacle which will accept the tool’s plug. When using an extension cord, be sure to use one heavy enough to carry the current of the tool. An undersized cord will cause a drop in line voltage, resulting in loss of power and overheating. Fig. DD, shows the correct gauge to use depending on the cord length. If in doubt, use the next heavier gauge. The smaller the gauge number, the heavier the cord.

MINIMUM GAUGE EXTENSION CORD

RECOMMENDED SIZES FOR USE WITH STATIONARY ELECTRIC TOOLS

Ampere

Volts

Total Length of

Gauge of

Rating

 

Cord in Feet

Extension Cord

0-6

120

up to 25

18 AWG

0-6

120

25-50

16 AWG

0-6

120

50-100

16 AWG

0-6

120

100-150

14 AWG

6-10

120

up to 25

18 AWG

6-10

120

25-50

16 AWG

6-10

120

50-100

14 AWG

6-10

120

100-150

12 AWG

10-12

120

up to 25

16 AWG

10-12

120

25-50

16 AWG

10-12

120

50-100

14 AWG

10-12

120

100-150

12 AWG

12-16

120

up to 25

14 AWG

12-16

120

25-50

12 AWG

12-16

120

GREATER THAN 50 FEET NOT RECOMMENDED

 

 

 

 

Fig. DD

MINIMUM GAUGE EXTENSION CORD

RECOMMENDED SIZES FOR USE WITH STATIONARY ELECTRIC TOOLS

Ampere

Volts

Total Length of

Gauge of

Rating

 

Cord in Feet

Extension Cord

0-6

240

up to 50

18 AWG

0-6

240

50-100

16 AWG

0-6

240

100-200

16 AWG

0-6

240

200-300

14 AWG

6-10

240

up to 50

18 AWG

6-10

240

50-100

16 AWG

6-10

240

100-200

14 AWG

6-10

240

200-300

12 AWG

10-12

240

up to 50

16 AWG

10-12

240

50-100

16 AWG

10-12

240

100-200

14 AWG

10-12

240

200-300

12 AWG

12-16

240

up to 50

14 AWG

12-16

240

50-100

12 AWG

12-16

240

GREATER THAN 100 FEET NOT RECOMMENDED

 

 

 

 

Fig. DD

OPERATING INSTRUCTIONS

FOREWORD

Delta Model 37-070 is a 6" Variable Speed Bench Jointer with designed cutting capacity of 6" (152mm) width and 1/8" (3mm) depth. Unit includes; 10 amp, 120 volt motor with variable speed range from 6000 to 11,000 rpm and cutting speed range from 12,000 to 22,000 cpm, dust chute, center-mounted fence, two-knife cutterhead, cutterhead guard and lock, wrenches and push blocks.

UNPACKING AND CLEANING

Carefully unpack the tool and all loose items from the shipping container(s). Remove the protective coating from all unpainted surfaces. This coating may be removed with a soft cloth moistened with kerosene (do not use acetone, gasoline or lacquer thinner for this purpose). After cleaning, cover the unpainted sufaces with a good quality household floor paste wax.

5

Image 5
Contents Variable Speed Bench Jointer Always Wear EYE Protection Safety RulesAdditional Safety Rules for Jointers Power Connections Connecting Tool to Power SourceExtension Cords Unpacking and CleaningDefinitions Jointing and Planing Operations Page Assembling Fence Assembly InstructionsPage Assembling Cutterhead Lock Assembling Cutterhead GuardLocking Switch OFF Position Operating Controls and AdjustmentsFastening Jointer to Supporting Surface Starting Stopping JointerDepth CUT Adjustment Speed Control ChartFence Adjustments Variable Speed ControlPage SET TOO LOW Adjusting KnivesCord Storage Chip and Dust ChuteOperation Placement of Hands During FeedingJointing AN Edge Push BlocksDirection of Grain Planing Warped PiecesPlaning Short Or Thin Work Belt Replacement MaintenancePARTS, Service or Warranty Assistance AccessoriesPage Maryland