Grizzly G1182HW Circuit Requirements, 110V Operation, Extension Cords, Grounding

Page 8

SECTION 2: CIRCUIT REQUIREMENTS

110V Operation

The Model G1182 Jointer Series is wired for 110/120V, single- phase operation. The 1 H.P. motor is dual voltage; however, we do not recom- mend converting to 220V because the magnetic switch is only rated for 110V. The motor will safe- ly draw 14 amps at 110V. If you operate this machine on any circuit that is already close to its capacity, it might blow a fuse or trip a circuit breaker. However, if an unusual load does not exist and a power failure still occurs, contact a qualified electrician or our service department.

A 15 amp fuse or circuit breaker should be used when fusing this (tool description). Circuit break- ers rated any higher may not be adequate to pro- tect the circuit from power surges.

Extension Cords

If you find it necessary to use an extension cord with the Model G1182 series of jointers, make sure the cord is rated Hard Service (grade S) or better. Refer to the chart in the standard safety instructions to determine the minimum gauge for the extension cord. The extension cord must also contain a ground wire and plug pin. Always repair or replace extension cords when they become worn or damaged.

Grounding

In the event of an electrical short, grounding reduces the risk of electric shock by providing electric current a path of least resistance. This tool is equipped with a power cord having an equipment-grounding conductor. See Figure 1. The outlet must be properly installed and ground- ed in accordance with all local codes and ordi- nances.

This equipment must be grounded. Verify that any existing electrical outlet and circuit you intend to plug into is actually grounded. Under no cir- cumstances should the grounding pin from any three-pronged plug be removed. Serious injury may occur.

Figure 1A. Do not remove grounding pin.

Figure 1. Typical 110V 3-prong plug and outlet.

-6-

G1182 6" Series Jointers

Image 8
Contents 47 HEAVY-DUTY Jointer Page G1182 Series Jointers Table Of Contents Safety Safety Instructions For Power ToolsLength AMP Rating Additional Safety Instructions For Jointers Never Joint end grainCircuit Requirements 110V OperationExtension Cords GroundingIntroduction CommentaryUnpacking Piece InventoryG1182Z layout Clean Up Site ConsiderationsAssembly Beginning AssemblyAttaching the motor G1182 6 Series Jointers Jointer to Stand Belt FenceCutter Guard Belt Guard Belt guard attachmentKnife Setting Gauge Pedestal SwitchKnives AdjustmentsTable Gibs Adjustments Using Jack Screws Adjustments Using Springs Outfeed TableInfeed Table Table stop bolt and check nutFence Stop Location of stop bolt and stop tabG1182 6 Series Jointers Operations Test Run Stock InspectionEdge Joining Beveling Fence position for bevel jointing G1182 6 Series JointersSurface Planing Rabbet CutsMaintenance GeneralTables LubricationClosure Machine Data Sheet Main Tables BaseStand for Jointer Model G1182Z & G1182ZHW HEX NUT 3⁄Fence Stop TABCutterhead Stand for Jointer Model G1182HW 308Handwheel Assembly for Model G1182HW & G1182ZHWPedestal Mounted Switch for Jointer Model G1182ZX 423 414 420 424 418 422 419 416 421 417Stand for Jointer Model G1182ZX Troubleshooting Symptom Possible Cause Corrective ActionWarranty and Returns Warranty Card CUT Along Dotted LineGrizzly INDUSTRIAL, INC G1182 6 Series Jointers G1182 6 Series Jointers