K. Basic Troubleshooting Techniques

Being familiar with the sequence of operation on Standard Controlled Operating Units or the operation of the Remote Thermostat Controlled Units is important. The following questions and answers may help to identify performance problems.

Environmental Effects - Cooling Mode

Is unit sized to room size area and heat load demand?

The number of people in the room, number of electrical devices, solar gains, etc. are all variable items that can affect proper sizing of the unit. Friedrich recommends that you consult with an applications engineer for proper sizing.

Environmental Effects - Heating Mode

Is unit properly sized to room area and heat load demand?

The number of people in the room, number of electrical devices, solar gains, etc. are all variable items that can affect proper sizing of the unit. Friedrich recommends that you consult with an applications engineer for proper sizing.

Is the outdoor temperature 60°F or below?

The unit is designed for outdoor temperatures above 60°F.

Is the indoor temperature 80°F or above?

Ambient indoor temperatures of 80°F or above will take a longer period of run time to cool down the area. Long run times may indicate that the unit is undersized.

Is indoor humidity high?

This condition will cause the unit to operate longer to remove humidity before noticing any cooling effect.

Is the outdoor temperature 70°F or above?

The unit is designed for outdoor temperatures below 70°F.

Is the indoor temperature 60°F or below? Ambient indoor temperatures of 60°F or below will take a longer period of run time to heat the area. Long run times may indicate that the unit is undersized.

Has the room area been increased where the unit is located?

If the area where the unit is located has been increased, the unit may not provide adequate heat.

Has the heat load been increased by additional devices such as computer equipment, or has the room area been increased where the unit is located?

If conditions have changed, the unit may not be able to cool and condition as effectively as previously planned.

Insufficient Maintenance and Inspection

Installation errorsarethe most common cause ofpoor performance. Please follow installation instructions carefully. If other problems exist, see Maintenance and Inspection Troubleshooting Guide below.

Maintenance and Inspection Troubleshooting Guide

CAUSE

RESULT

 

 

System is not serviced or inspected

Can result in premature component failures, poor performance and

regularly (semiannually or annually).

increased operating costs.

Air filters are not cleaned regularly and

May result in poor cooling, icing and water problems as well as

become blocked with particles.

component failures and increased operating costs.

Condenser coil not maintained

May result in poor cooling, component failures and increased costs.

properly (blocked with particles).

 

Evaporator coil not maintained properly

May result in poor cooling, icing and water problems, and increased

(blocked with particles).

operating costs.

Components that show signs of fatigue

May result in multiple service calls, poor performance and

- not replaced.

increased operating costs.

Condensate drains and drain lines not

May result in water and odor problems.

maintained.

 

 

 

23

Image 23
Contents Ptac Table of Contents Model Number Code Building Elevation Ptac Installation RecommendationsDigital Temperature Friedrich Digital Control FeaturesHeat Pump Mode Internal Drain optional for new construction Installation Instructions PXDR10 Drain KitDrain Kit Location and Installation Drain Kit Installation External Drain for new construction or unit replacementDrain Tube Installation Cover Plate InstallationTypical Wall Sleeve Installation Wall Sleeve Installation Instructions PdxwsLintel Installation DimensionsWall Sleeve Extension Sealant Locations Section II Deep Wall Installation PxweExtension Installation Standard Grille Installation Instructions Model Pxga Standard Grille30A Lcdi Device Power Cord Information 230/208V models onlyElectrical Rating Tables 15/20A Lcdi DeviceSection III Chassis Installation Installation ChecklistWall sleeve Wall sleeve flange Chassis flange and gasket Digital Control User Input Configuration Dip Switch SettingFactory Dip Switch Configuration Digital Control Operation Remote Thermostat Control board with optional Pdxrt escutcheon kit installedRemote Thermostat and Low Voltage Control Connections Auxiliary Fan Control Fresh Air Vent ControlAir Discharge Grille Desk Control TerminalsStart-up Checklist Line Voltage Connections Appendix a Electrical Wiring for 265 Volt ModelsComponents Routine MaintenanceInsufficient Maintenance and Inspection Basic Troubleshooting TechniquesEnvironmental Effects Cooling Mode Environmental Effects Heating ModeTest Mode Digital Control Diagnostics and Test ModeDiagnostics Friedrich Ptac Accessories Pxse Friedrich Air Conditioning Company 920-087-04

HEAT PUMPS specifications

Friedrich Heat Pumps are designed to provide efficient heating, cooling, and dehumidification solutions for various applications, including residential, commercial, and industrial settings. Renowned for their innovative technology and commitment to sustainability, Friedrich has become a recognized name in the HVAC industry.

One of the primary features of Friedrich Heat Pumps is their energy efficiency. These systems utilize advanced inverter technology, allowing the compressor to adjust its speed according to current heating or cooling demands. This leads to significant energy savings compared to traditional systems, which operate at a constant speed. By maintaining a more consistent indoor temperature, Friedrich Heat Pumps reduce energy consumption and lower utility bills.

In addition to energy efficiency, Friedrich offers a variety of models to suit different needs. The range includes air-source heat pumps, which extract heat from the outdoor air, and geothermal heat pumps, which utilize the stable temperatures found underground. This versatility allows users to select a system that best fits their specific climate conditions and application requirements.

Friedrich Heat Pumps also feature smart technology integration, making them a perfect choice for modern smart homes. Many models come equipped with Wi-Fi capabilities, allowing users to control their system remotely through a smartphone app. This feature not only enhances convenience but also allows for enhanced energy management, enabling users to monitor and adjust their heating and cooling schedules for optimal efficiency.

Another notable characteristic is their quiet operation. Friedrich Heat Pumps are engineered with noise-reducing features, making them suitable for residential areas where noise may be a concern. This focus on quiet performance ensures that users can enjoy a comfortable indoor environment without disruptive sound.

Durability and reliability are also key attributes of Friedrich Heat Pumps. Built with high-quality materials and rigorous testing processes, these systems are designed to withstand varying environmental conditions and provide long-lasting performance. Regular maintenance is further simplified with easy access to essential components, prolonging the system's lifespan.

In conclusion, Friedrich Heat Pumps stand out for their energy efficiency, innovative technologies, and superb performance characteristics. With options suitable for a wide array of applications, they are an excellent choice for anyone looking to enhance their indoor climate control while reducing their environmental footprint. Their advanced features, silent operation, and reliability make them a preferred option for modern heating and cooling solutions. Whether for residential or commercial use, Friedrich Heat Pumps offer a perfect blend of comfort, efficiency, and sustainability.