Chauvet DVM-HR user manual Meters by 4.5 meters, Meters by 9 meters

Page 18

Setup

16:9 Aspect Ratio

8 meters by 4.5 meters

Front View

256 pixels wide or

256 vertical lines

96 pixels wide or

 

96 pixels wide or

 

 

64 pixels wide or

96 vertical lines

 

96 vertical lines

 

 

64 vertical lines

 

 

 

System Information

J1

J1

J1

 

Vertical lines: 256

J2

J2

J2

Horizontal lines: 144

Resolution: 256 x 144 pix

J3

J3

J3

Size: 8m x 4.5m

Panels: 144 (16 x 9)

J4

J4

J4

Power: 8 x 20A (110V)

Drivers: 3

J5

J5

J5

Net Out: Out 1

J Ports: 1 ~ 9

J6

J6

J6

 

 

J7

J7

J7

 

J8

J8

J8

 

J9

J9

J9

Starting Address: 0

Starting Address: 96

Starting Address: 192

Driver 3

Driver 2

Driver 1

Driver 1

Width = 64

JP1

1

2

3

4

5

6

7

8

9

10 11 12

0

1

1

0

0

0

0

0

0

0

0

0

 

 

Start = 192

JP2

1

2

3

4

5

6

7

8

9

10 11 12

1

1

0

0

0

1

1

0

0

0

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Driver 3

 

 

 

 

 

 

 

 

 

 

 

 

 

Width = 96

JP1

1

2

3

4

5

6

7

8

9

10 11 12

0

1

0

1

0

0

0

0

0

0

0

0

 

 

Start = 0

JP2

1

2

3

4

5

6

7

8

9

10 11 12

0

0

0

0

0

1

1

0

0

0

0

0

 

 

Driver 2

Width = 96

JP1

1

2

3

4

5

6

7

8

9

10 11 12

0

1

0

1

0

0

0

0

0

0

0

0

 

 

Start = 96

JP2

1

2

3

4

5

6

7

8

9

10 11 12

1

0

0

0

0

1

1

0

0

0

0

1

 

 

16 meters by 9 meters

By now you should have a good understanding of the steps involved in configuring fairly simple sizes. The following example will not illustrate the grid but will present all dipswitch settings in a table format and relevant system information for a 16 by 9 meter matrix. J1~J8 are used for Net OUT2 only.

Driver

Width = 64

JP1

1

2

3

4

5

6

7

8

9

10 11 12

0

1

0

0

0

0

0

0

0

0

0

0

1

 

JP2

1

2

3

4

5

6

7

8

9

10 11 12

Start = 192

1

1

1

0

0

1

1

0

0

0

0

1

 

 

Width = 64

JP1

1

2

3

4

5

6

7

8

9

10 11 12

0

1

0

1

0

0

0

0

0

0

0

0

2

 

JP2

1

2

3

4

5

6

7

8

9

10 11 12

Start = 192

0

1

1

0

0

1

1

0

0

0

0

0

 

 

Width = 64

JP1

1

2

3

4

5

6

7

8

9

10 11 12

0

1

0

1

0

0

0

0

0

0

0

0

3

 

JP2

1

2

3

4

5

6

7

8

9

10 11 12

Start = 192

0

0

0

0

0

1

1

0

0

0

0

1

 

 

Width = 64

JP1

1

2

3

4

5

6

7

8

9

10 11 12

0

1

0

1

0

0

0

0

0

0

0

0

4

 

JP2

1

2

3

4

5

6

7

8

9

10 11 12

Start = 192

1

1

0

0

0

1

1

0

0

0

0

0

 

 

Width = 64

JP1

1

2

3

4

5

6

7

8

9

10 11 12

0

1

0

1

0

0

0

0

0

0

0

0

5

 

JP2

1

2

3

4

5

6

7

8

9

10 11 12

Start = 192

1

0

0

0

0

1

1

0

0

0

0

1

 

 

Width = 64

JP1

1

2

3

4

5

6

7

8

9

10 11 12

0

1

0

1

0

0

0

0

0

0

0

0

6

 

JP2

1

2

3

4

5

6

7

8

9

10 11 12

Start = 192

0

0

0

0

0

1

1

0

0

0

0

0

 

 

System Information

 

 

 

 

 

 

 

 

 

 

 

 

Vertical lines: 512

 

 

 

 

Power: 96 x 20A (110V)

Horizontal lines: 384

 

 

 

Drivers: 12

 

 

 

 

 

Resolution: 512 x 384 pix

 

 

 

Net Out: Out1 & Out2

 

Size: 16m x 9m

 

 

 

 

J Ports: Out1: J1 ~ J16

Panels: 768 (32 x 24)

 

 

 

J Ports: Out2: J1 ~ J8

 

Driver

Width = 64

JP1

7

JP2

Start = 192

Width = 64

JP1

8

JP2

Start = 192

Width = 64

JP1

9

JP2

Start = 192

Width = 64

JP1

10

JP2

Start = 192

Width = 64

JP1

11

JP2

Start = 192

Width = 64

JP1

12

JP2

Start = 192

1 2 3 4 5 6 7 8 9 10 11 12

0 1 0 0 0 0 0 0 0 0 0 0

1 2 3 4 5 6 7 8 9 10 11 12

1 1 1 0 0 1 1 0 0 0 0 1

1 2 3 4 5 6 7 8 9 10 11 12

0 1 0 1 0 0 0 0 0 0 0 0

1 2 3 4 5 6 7 8 9 10 11 12

0 1 1 0 0 1 1 0 0 0 0 0

1 2 3 4 5 6 7 8 9 10 11 12

0 1 0 1 0 0 0 0 0 0 0 0

1 2 3 4 5 6 7 8 9 10 11 12

0 0 0 0 0 1 1 0 0 0 0 1

1 2 3 4 5 6 7 8 9 10 11 12

0 1 0 1 0 0 0 0 0 0 0 0

1 2 3 4 5 6 7 8 9 10 11 12

1 1 0 0 0 1 1 0 0 0 0 0

1 2 3 4 5 6 7 8 9 10 11 12

0 1 0 1 0 0 0 0 0 0 0 0

1 2 3 4 5 6 7 8 9 10 11 12

1 0 0 0 0 1 1 0 0 0 0 1

1 2 3 4 5 6 7 8 9 10 11 12

0 1 0 1 0 0 0 0 0 0 0 0

1 2 3 4 5 6 7 8 9 10 11 12

0 0 0 0 0 1 1 0 0 0 0 0

DV Wall System User Manual

18

2007-02-05/16:45

Image 18
Contents DVM-HR Table of Contents Contact Us Before You BeginUnpacking Instructions Your shipment may include the followingProtection against Fire & Burns Important Safety InformationProtection against Electric Shock Protection against Injury to personsOverview FeaturesIntroduction Computer System RequirementsDV Wall 1024 Panel Product OverviewIntroduction Square panels = 1 square meter 2007-02-05/1645Power Cable Configuration Hardware SetupAC Power ResolutionD16 Maximum System ConfigurationOther Configuration Examples D14Setup Mounting SystemM10 Hex bolts Flying bracket attachmentJoining bracket Hanging eye hookSignal & Power Configuration Each DV Wall panel consumes 109W of powerDV-Wall Driver J10 J11 J12 J13 J14 J15 J16 Rear View Panels = 1 meter²JP1 Dipswitches Dipswitch SettingsJP1 Dipswitch Default Off Default On SubtractJP2 Dipswitch Horizontal LineTransmitter Card Installation Data Out 1 & Data Out 2 connectorsDC External Power Input Transmitter CardMeters by 3 meter Example System ConfigurationsAspect Ratio Meters by 6 metersMeters by 12 meters Front View J9Meters by 4.5 meters Meters by 9 metersSpecial Applications PatternAppendix Returns ProcedureMaintenance ClaimsTechnical Specifications per panel Technical Support