3. Hardware Setup

 

AC Power

Warning!

Verify that the power requirement label on your unit matches the line voltage

 

applied. All fixtures must be connected to circuits with a suitable Earth Ground.

 

• To determine the power requirements for a particular fixture, see the label affixed to the back plate

 

of the fixture or refer to the fixture’s specifications chart.

 

• A fixture’s listed current rating is its average current draw under normal conditions.

 

• All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat

 

(variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is used solely for a 0%

 

to 100% switch.

 

• Before applying power to a fixture, check that the source voltage matches the fixture’s

 

requirement.

 

• All fixtures must be connected to circuits with a suitable Earth Ground.

Power Cable Configuration

CABLE

Pin

International

Screw Color

 

BROWN

Live

L

Yellow or Brass

 

BLUE

Neutral

N

Silver

 

YELLOW/GREEN

Earth

EG (Ground)

Green

System Limitations

 

 

VERTICAL PANELS (DOWN)

 

 

 

MINIMUM

 

1 panel = 16 rows of LED clusters or 16 vertical pixels/lines

 

 

MAXIMUM WITH 1 DRIVER

16 panels = 256 rows of LED clusters or 256 vertical pixels/lines

 

 

MAXIMUM WITH 2+ DRIVERS

32 panels = 512 rows of LED clusters or 512 vertical pixels

HORIZONTAL PANELS (ACROSS)

 

 

 

MINIMUM

 

1 panel = 16 columns of LED clusters or 16 horizontal pixels/lines

 

 

MAXIMUM WITH 1 DRIVER

6 panels = 96 columns of LED clusters or 96 horizontal pixels/lines

 

 

MAXIMUM WITH 2+ DRIVERS

48 panels = 768 columns of LED clusters or 768 horizontal pixels

RESOLUTION

 

 

 

 

MINIMUM

 

16 pixels X 16 pixels

 

 

MAXIMUM WITH 1 DRIVER

96 pixels X 128 pixels

 

 

MAXIMUM WITH 2+ DRIVERS

768 pixels X 512 pixels

 

 

 

 

 

DV Wall System User Manual

7

2007-02-05/16:45

Image 7
Contents DVM-HR Table of Contents Your shipment may include the following Before You BeginUnpacking Instructions Contact UsProtection against Injury to persons Important Safety InformationProtection against Electric Shock Protection against Fire & BurnsComputer System Requirements FeaturesIntroduction OverviewSquare panels = 1 square meter 2007-02-05/1645 Product OverviewIntroduction DV Wall 1024 PanelResolution Hardware SetupAC Power Power Cable ConfigurationD14 Maximum System ConfigurationOther Configuration Examples D16Mounting System SetupHanging eye hook Flying bracket attachmentJoining bracket M10 Hex boltsEach DV Wall panel consumes 109W of power Signal & Power ConfigurationJ10 J11 J12 J13 J14 J15 J16 Rear View Panels = 1 meter² DV-Wall DriverDefault Off Default On Subtract Dipswitch SettingsJP1 Dipswitch JP1 DipswitchesHorizontal Line JP2 DipswitchTransmitter Card Data Out 1 & Data Out 2 connectorsDC External Power Input Transmitter Card InstallationMeters by 6 meters Example System ConfigurationsAspect Ratio Meters by 3 meterFront View J9 Meters by 12 metersMeters by 9 meters Meters by 4.5 metersPattern Special ApplicationsClaims Returns ProcedureMaintenance AppendixTechnical Support Technical Specifications per panel