HEAT PUMP HEATING PERFORMANCE CONTINUED
INDOOR AIR |
|
|
|
|
|
|
|
|
| OUTDOOR COIL ENTERING AIR TEMPERATURES deg F |
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
| 7 |
|
| 17 |
|
| 27 |
|
| 37 |
|
| 47 |
|
| 57 |
|
| 67 |
| |
EDB | CFM | Capacity MBtuh | Total | Capacity MBtuh | Total | Capacity MBtuh | Total | Capacity MBtuh | Total | Capacity MBtuh | Total | Capacity MBtuh | Total | Capacity MBtuh | Total | Capacity MBtuh | Total | ||||||||
|
| System |
|
| System |
|
| System |
|
| System |
|
| System |
|
| System |
|
| System |
|
| System | ||
|
| Total | Integ* | KW† | Total | Integ* | KW† | Total | Integ* | KW† | Total | Integ* | KW† | Total | Integ* | KW† | Total | Integ* | KW† | Total | Integ* | KW† | Total | Integ* | KW† |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
| 875 | 10.94 | 10.07 | 1.72 | 14.09 | 12.95 | 1.81 | 17.44 | 15.90 | 1.89 | 21.04 | 18.69 | 1.98 | 24.99 | 22.74 | 2.08 | 29.49 | 29.49 | 2.21 | 34.39 | 34.39 | 2.36 | 39.81 | 39.81 | 2.55 |
65 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1000 | 11.16 | 10.26 | 1.73 | 14.33 | 13.17 | 1.81 | 17.72 | 16.16 | 1.88 | 21.36 | 18.97 | 1.96 | 25.39 | 23.10 | 2.05 | 29.96 | 29.96 | 2.17 | 34.98 | 34.98 | 2.31 | 40.60 | 40.60 | 2.48 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1125 | 11.34 | 10.44 | 1.75 | 14.53 | 13.35 | 1.81 | 17.96 | 16.37 | 1.88 | 21.61 | 19.20 | 1.95 | 25.72 | 23.40 | 2.03 | 30.35 | 30.35 | 2.14 | 35.46 | 35.46 | 2.27 | 41.24 | 41.24 | 2.43 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 875 | 10.36 | 9.53 | 1.79 | 13.60 | 12.50 | 1.88 | 16.95 | 15.46 | 1.97 | 20.58 | 18.28 | 2.07 | 24.47 | 22.26 | 2.18 | 28.94 | 28.94 | 2.32 | 33.75 | 33.75 | 2.47 | 39.12 | 39.12 | 2.67 |
70 | 1000 | 10.61 | 9.76 | 1.80 | 13.85 | 12.72 | 1.88 | 17.24 | 15.72 | 1.96 | 20.90 | 18.56 | 2.05 | 24.86 | 22.62 | 2.15 | 29.40 | 29.40 | 2.27 | 34.35 | 34.35 | 2.41 | 39.85 | 39.85 | 2.59 |
| 1125 | 10.80 | 9.94 | 1.82 | 14.06 | 12.92 | 1.89 | 17.48 | 15.93 | 1.96 | 21.16 | 18.80 | 2.04 | 25.19 | 22.92 | 2.13 | 29.78 | 29.78 | 2.24 | 34.81 | 34.81 | 2.37 | 40.44 | 40.44 | 2.54 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 875 | 9.76 | 8.98 | 1.86 | 13.04 | 11.99 | 1.96 | 16.47 | 15.01 | 2.06 | 20.10 | 17.85 | 2.17 | 23.98 | 21.82 | 2.28 | 28.30 | 28.30 | 2.42 | 33.12 | 33.12 | 2.59 | 38.41 | 38.41 | 2.78 |
75 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1000 | 9.99 | 9.19 | 1.87 | 13.29 | 12.22 | 1.96 | 16.76 | 15.28 | 2.05 | 20.44 | 18.15 | 2.15 | 24.35 | 22.16 | 2.25 | 28.84 | 28.84 | 2.38 | 33.70 | 33.70 | 2.52 | 39.13 | 39.13 | 2.70 | |
| 1125 | 10.18 | 9.36 | 1.88 | 13.51 | 12.42 | 1.97 | 17.00 | 15.50 | 2.05 | 20.71 | 18.39 | 2.14 | 24.65 | 22.43 | 2.23 | 29.22 | 29.22 | 2.35 | 34.18 | 34.18 | 2.48 | 39.70 | 39.70 | 2.65 |
| Heating Indoor Model | Capacity | Power | Furnace Model |
| Heating Indoor Model | Capacity | Power | Furnace Model |
| *FX4CNF030 | 1.00 | 1.00 |
|
| CSPH*3612A** | 0.98 | 0.97 | 315(A,J)AV048090 |
|
|
|
|
|
|
|
|
|
|
| FE4ANF002 | 0.99 | 0.99 |
| CAP**3621A** | 0.98 | 0.99 | 315(A,J)AV060110 | |
| FE4ANF003 | 0.98 | 0.98 |
|
| CNPH*3017A** | 0.98 | 1.00 | 315(A,J)AV060110 |
|
|
|
|
|
|
|
|
|
|
| FE4ANF005 | 0.99 | 0.95 |
| CNPH*3617A** | 0.98 | 1.00 | 315(A,J)AV060110 | |
| FE5ANB004 | 0.99 | 0.92 |
|
| CNPV*3621A** | 0.98 | 1.00 | 315(A,J)AV060110 |
| FF1ENP030 | 1.01 | 1.07 |
|
| CSPH*3012A** | 0.98 | 1.00 | 315(A,J)AV060110 |
| FF1ENP036 | 1.02 | 1.06 |
|
| CSPH*3612A** | 0.98 | 0.97 | 315(A,J)AV060110 |
|
|
|
|
|
|
|
|
|
|
| FV4BNF002 | 0.99 | 0.99 |
| CNPH*3017A** | 0.98 | 1.00 | 315(A,J)AV066135 | |
| FV4BNF003 | 0.98 | 0.98 |
|
| CNPH*3617A** | 0.98 | 1.00 | 315(A,J)AV066135 |
|
|
|
|
|
|
|
|
|
|
| FV4BNF005 | 0.99 | 0.95 |
| CSPH*3012A** | 0.98 | 1.00 | 315(A,J)AV066135 | |
| FX4CN(B,F)036 | 1.01 | 1.00 |
|
| CSPH*3612A** | 0.98 | 0.97 | 315(A,J)AV066135 |
| FY4ANF030 | 1.02 | 1.05 |
|
| CNPH*3017A** | 0.98 | 1.00 | 315(A,J)AV066155 |
| FY4ANF036 | 1.02 | 1.06 |
|
| CNPH*3617A** | 0.98 | 1.00 | 315(A,J)AV066155 |
|
|
|
|
|
|
|
|
|
|
| CAP**3014A** | 1.02 | 1.06 |
| CSPH*3012A** | 0.98 | 1.00 | 315(A,J)AV066155 | |
27 | CAP**3017A** | 1.02 | 1.06 |
|
| CSPH*3612A** | 0.98 | 0.97 | 315(A,J)AV066155 |
|
|
|
|
|
|
|
|
|
|
| CAP**3614A** | 0.99 | 1.02 |
| CNPH*3017A** | 0.98 | 1.01 | 355AAV042040 | |
| CAP**3617A** | 1.02 | 1.06 |
|
| CNPH*3617A** | 0.98 | 1.01 | 355AAV042040 |
|
|
|
|
|
|
|
|
|
|
| CAP**3621A** | 1.02 | 1.06 |
| CSPH*3012A** | 0.98 | 1.01 | 355AAV042040 | |
| CNPF*3618A** | 1.02 | 1.06 |
|
| CSPH*3612A** | 0.98 | 0.98 | 355AAV042040 |
| CNPH*3017A** | 1.02 | 1.06 |
|
| CAP**3017A** | 0.98 | 1.01 | 355AAV042060 |
| CNPH*3617A** | 1.02 | 1.06 |
|
| CAP**3617A** | 0.98 | 1.01 | 355AAV042060 |
|
|
|
|
|
|
|
|
|
|
| CNPV*3014A** | 1.02 | 1.06 |
| CNPH*3017A** | 0.98 | 1.01 | 355AAV042060 | |
| CNPV*3017A** | 1.02 | 1.06 |
|
| CNPH*3617A** | 0.98 | 1.01 | 355AAV042060 |
|
|
|
|
|
|
|
|
|
|
| CNPV*3617A** | 1.02 | 1.06 |
| CNPV*3017A** | 0.98 | 1.01 | 355AAV042060 | |
| CNPV*3621A** | 1.02 | 1.06 |
|
| CNPV*3617A** | 0.98 | 1.01 | 355AAV042060 |
| CSPH*3012A** | 1.02 | 1.05 |
|
| CSPH*3012A** | 0.98 | 1.01 | 355AAV042060 |
| CSPH*3612A** | 1.02 | 1.02 |
|
| CSPH*3612A** | 0.98 | 0.98 | 355AAV042060 |
| CAP**3014A** | 0.98 | 1.02 | 315(A,J)AV036070 |
| CAP**3621A** | 0.98 | 1.00 | 355AAV042080 |
| CAP**3614A** | 0.95 | 0.98 | 315(A,J)AV036070 |
| CNPH*3017A** | 0.98 | 1.01 | 355AAV042080 |
|
|
|
|
|
|
|
|
|
|
| CNPH*3017A** | 0.98 | 1.01 | 315(A,J)AV036070 | CNPH*3617A** | 0.98 | 1.01 | 355AAV042080 | |
| CNPH*3617A** | 0.98 | 1.01 | 315(A,J)AV036070 |
| CNPV*3621A** | 0.98 | 1.01 | 355AAV042080 |
|
|
|
|
|
|
|
|
|
|
| CNPV*3014A** | 0.98 | 1.02 | 315(A,J)AV036070 | CSPH*3012A** | 0.98 | 1.01 | 355AAV042080 | |
| CSPH*3012A** | 0.98 | 1.01 | 315(A,J)AV036070 |
| CSPH*3612A** | 0.98 | 0.98 | 355AAV042080 |
| CSPH*3612A** | 0.98 | 0.98 | 315(A,J)AV036070 |
| CAP**3621A** | 0.98 | 1.00 | 355AAV060080 |
| CAP**3017A** | 0.98 | 1.01 | 315(A,J)AV048090 |
| CNPH*3017A** | 0.98 | 1.01 | 355AAV060080 |
|
|
|
|
|
|
|
|
|
|
| CAP**3617A** | 0.98 | 1.00 | 315(A,J)AV048090 | CNPH*3617A** | 0.98 | 1.01 | 355AAV060080 | |
| CNPH*3017A** | 0.98 | 1.00 | 315(A,J)AV048090 |
| CNPV*3621A** | 0.98 | 1.01 | 355AAV060080 |
|
|
|
|
|
|
|
|
|
|
| CNPH*3617A** | 0.98 | 1.00 | 315(A,J)AV048090 | CSPH*3012A** | 0.98 | 1.01 | 355AAV060080 | |
| CNPV*3017A** | 0.98 | 1.00 | 315(A,J)AV048090 |
| CSPH*3612A** | 0.98 | 0.98 | 355AAV060080 |
| CNPV*3617A** | 0.98 | 1.00 | 315(A,J)AV048090 |
| CAP**3621A** | 0.98 | 1.00 | 355AAV060100 |
| CSPH*3012A** | 0.98 | 1.00 | 315(A,J)AV048090 |
| CNPH*3017A** | 0.98 | 1.01 | 355AAV060100 |
Heating Indoor Model | Capacity | Power | Furnace Model |
CNPH*3617A** | 0.98 | 1.01 | 355AAV060100 |
|
|
|
|
CNPV*3621A** | 0.98 | 1.01 | 355AAV060100 |
CSPH*3012A** | 0.98 | 1.00 | 355AAV060100 |
|
|
|
|
CSPH*3612A** | 0.98 | 0.97 | 355AAV060100 |
CNPH*3017A** | 0.98 | 1.01 | 355AAV060120 |
CNPH*3617A** | 0.98 | 1.01 | 355AAV060120 |
CSPH*3012A** | 0.98 | 1.01 | 355AAV060120 |
|
|
|
|
CSPH*3612A** | 0.98 | 0.98 | 355AAV060120 |
See notes on pg. 31