Accessory Description and Usage (Listed Alphabetically) - CONTINUED

265A

10. Outdoor Air Temperature Sensor

Designed for use with Bryant Thermostats listed in this publication. This device enables the thermostat to display the outdoor temperature. This device also is required to enable special thermostat features such as auxiliary heat lock out.

Usage Guideline:

Suggested for all Bryant thermostats listed in this publication.

11. Outdoor Thermostat

An SPDT temperature-actuated switch which turns on supplemental electric heaters when outdoor air temperature drops below a user-selected set point.

Usage Guideline:

Electric supplemental heat applications in non-variable speed indoor units when electric heat staging is desired.

12. Secondary Outdoor Thermostat

An SPDT temperature-actuated switch which turns on third-stage of supplemental electric heaters when outdoor air temperature drops below the second-stage set point.

Usage Guideline:

Outdoor thermostat applications where electric heater is capable of 3-stage operation.

13. Sound Hood

Wraparound sound reducing cover for the compressor. Reduces the sound level by about 2 dBA.

Usage Guideline:

Suggested when unit is installed closer than 15 ft. to quiet areas, bedrooms, etc.

Suggested when unit is installed between two houses less than 10 ft. apart.

14. Thermostatic Expansion Valve (TXV) Bi-Flow

Amodulating flow-control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator.

Usage Guideline:

Accessory required to meet ARI rating and system reliability, where indoor not equipped.

Required in all heat pump applications designed with Puron refrigerant.

15. Time-Delay Relay

An SPST delay relay which briefly continues operation of indoor blower motor to provide additional cooling after the compressor cycles off.

Note: Most indoor unit controls include this feature. For those that do not, use the guideline below.

Usage Guideline:

Accessory required to meet ARI rating, where indoor not equipped.

6

Image 6
Contents Industry Leading Features / Benefits Product DataModel Number Nomenclature ISOPhysical Data Unit Size SeriesAccessories Accessory ThermostatsAccessory Usage Guideline ApplicationsOutdoor Air Temperature Sensor Electrical Data Charging Subcooling TXV-TYPE Expansion DeviceDimensions 265A Balance Point Worksheet Furnace Model Combination RatingsCapacity Factory Standard Enhance Rating030--B CAP**3017A 28,800 FY4ANF042 FE4ANB006FV4BNB006 036--BFY4ANF048 042--BCAP**4821A 41,500 048--B FY4ANB060060--B Cooling Indoor Model Capacity Power Furnace Model Detailed Cooling Capacities700 800900 FY4ANF030 FY4ANF036 1200 FY4ANF036 FY4ANF0421050 13501400 FY4ANF042 FY4ANF0481225 15751600 FE4ANB006 FE4ANF005 FV4BNB006 FV4BNF005FY4ANB060 FY4ANF048 18002000 FE4ANB006 FV4BNB006 FY4ANB0601750 2250Heat Pump Heating Performance Outdoor Coil Entering AIR Temperatures deg F Total IntegFX4CNF030 CSPH*3612A 315A,JAV048090 FX4CNB,F042 CNPH*4221A 315A,JAV060110 FX4CNB,F048 CAP**4224A 315A,JAV066135 265ANA048-- B Outdoor Section With FX4CNF060 Indoor Section 265ANA060-- B Outdoor Section With FX4CNF060 Indoor Section Guide Specifications General Products