Bryant 265A warranty Physical Data, Unit Size Series

Page 3

PHYSICAL DATA

UNIT SIZE SERIES

018---B

024---B

030---B

036---B

042---B

048---B

060---B

Operating Weight (lb)

198

244

280

299

318

325

307

Shipping Weight (lb)

232

280

310

335

354

361

344

Compressor Type

 

 

 

Scroll

 

 

 

REFRIGERANT

 

 

 

Puron(R--- 410A)

 

 

 

Control

 

 

TXV (Puron Hard Shutoff)

 

 

Charge (lb)

6.13

10.4

12

14.8

14.2

12.6

12.5

COND FAN

 

 

Propeller Type, Direct Drive

 

 

Air Discharge

 

 

 

Vertical

 

 

 

Air Qty (CFM)

2595

2595

3265

3265

3265

3673

3673

Motor HP

1/10

1/10

1/5

1/5

1/5

1/4

1/4

Motor RPM

800

800

800

800

800

800

800

COND COIL

 

 

 

 

 

 

 

Face Area (Sq ft)

16.26

18.3

20.33

24.4

24.4

24.4

22.4

Fins per In.

20

20

20

20

20

20

20

Rows

1

1

1

2

2

2

2

Circuits

4

5

6

5

7

8

9

VALVE CONNECT. (In. ID)

 

 

 

 

 

 

 

Vapor

5/8”

5/8”

3/4”

3/4”

7/8”

7/8”

7/8”

Liquid

 

 

 

3/8”

 

 

 

REFRIGERANT TUBES* (In. OD)

 

 

 

 

 

 

 

Vapor (0---80 Ft Tube Length)

5/8”

5/8”

3/4”

3/4”

7/8”

7/8”

1--- 1/8”

Liquid (0---80 Ft Tube Length)

 

 

 

3/8”

 

 

 

*For tubing sets between 80 ft. and 200 ft. horizontal or 20 ft. vertical differential (250 ft. Total Equivalent Length), consult the Long---Line Guideline. Note: See unit Installation Instruction for proper installation.

VAPOR LINE SIZING AND COOLING CAPACITY LOSS

PURON 1-STAGE HEAT PUMP APPLICATIONS

LONG LINE APPLICATION: An application is considered

 

is above indoor unit, and 80 ft. when the outdoor unit is below

”Long line” when the total equivalent tubing length exceeds 80

 

the indoor unit. Refer to Accessory Usage Guideline below for

ft. or when there is more than 20 ft. vertical separation between

 

required accessories. See Long-Line Application Guideline for

indoor and outdoor units. These applications require additional

required piping and system modifications. Also, refer to the table

accessories and system modifications for reliable system

 

below for the acceptable vapor tube diameters based on the total

operation. The maximum allowable total equivalent length is 250

 

length to minimize the cooling capacity loss.

 

 

ft. The maximum vertical separation is 200 ft. when outdoor unit

 

 

 

 

 

 

 

 

 

 

 

Acceptable

Acceptable

 

 

Cooling Capacity Loss (%)Total Equivalent Line Length (ft.)

 

 

Unit Nominal

Liquid Line

Vapor Line

 

 

 

 

 

 

 

 

 

 

 

 

 

Standard Application

 

 

Long Line Application Requires Accessories

 

Size (Btuh)

Diameter OD

Diameters

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(in.)

OD (in.)

25

50

80

80+

100

125

150

175

200

 

225

250

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18000

3/8

1/2

1

2

3

3

4

 

6

7

8

9

 

10

12

1---Stage Puron

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5/8

0

0

1

1

1

 

1

2

2

3

 

3

3

HP

 

 

 

24000

3/8

5/8

0

1

1

1

2

 

3

3

4

4

 

5

6

1---Stage Puron

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3/4

0

0

0

0

0

 

1

1

1

1

 

1

2

HP

 

 

 

30000

 

5/8

1

2

3

3

3

 

4

5

6

7

 

8

9

1---Stage Puron

3/8

3/4

0

0

1

1

1

 

1

2

2

2

 

3

3

HP

 

7/8

0

0

0

0

0

 

1

1

1

1

 

1

1

 

 

 

 

36000

 

5/8

1

2

4

4

5

 

6

7

9

10

 

11

13

1---Stage Puron

3/8

3/4

0

0

1

1

1

 

2

2

3

3

 

4

4

HP

 

7/8

0

0

0

0

0

 

1

1

1

1

 

2

2

 

 

 

 

42000

3/8

3/4

0

1

2

2

2

 

3

4

4

5

 

6

6

1---Stage Puron

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7/8

0

0

1

1

1

 

1

2

2

2

 

3

3

HP

 

 

 

48000

3/8

3/4

0

1

2

2

3

 

4

5

5

6

 

7

8

1---Stage Puron

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7/8

0

0

1

1

1

 

2

2

2

3

 

3

4

HP

 

 

 

60000

 

3/4

1

2

4

4

5

 

6

7

9

10

 

11

12

1---Stage Puron

3/8

7/8

0

1

2

2

2

 

3

4

4

5

 

5

6

HP

 

1 1/8

0

0

0

0

1

1

1

1

1

 

1

2

 

 

 

Standard Length = 80 ft. or less total equivalent length

Applications in this area are long line. Accessories are required as shown recommended on Long Line Application Guidelines

Applications in this area may have height restrictions that limit allowable total equivalent length, when outdoor unit is below indoor unit See Long Line Application Guidelines

265A

3

Image 3
Contents Product Data Industry Leading Features / BenefitsISO Model Number NomenclatureUnit Size Series Physical DataAccessory Thermostats AccessoriesApplications Accessory Usage GuidelineOutdoor Air Temperature Sensor Charging Subcooling TXV-TYPE Expansion Device Electrical DataDimensions 265A Balance Point Worksheet Enhance Rating Combination RatingsCapacity Factory Standard Furnace Model030--B CAP**3017A 28,800 036--B FE4ANB006FV4BNB006 FY4ANF042042--B FY4ANF048CAP**4821A 41,500 FY4ANB060 048--B060--B Detailed Cooling Capacities Cooling Indoor Model Capacity Power Furnace Model700 800900 FY4ANF030 FY4ANF036 1350 FY4ANF036 FY4ANF0421050 12001575 FY4ANF042 FY4ANF0481225 14001800 FE4ANB006 FE4ANF005 FV4BNB006 FV4BNF005FY4ANB060 FY4ANF048 16002250 FE4ANB006 FV4BNB006 FY4ANB0601750 2000Heat Pump Heating Performance Total Integ Outdoor Coil Entering AIR Temperatures deg FFX4CNF030 CSPH*3612A 315A,JAV048090 FX4CNB,F042 CNPH*4221A 315A,JAV060110 FX4CNB,F048 CAP**4224A 315A,JAV066135 265ANA048-- B Outdoor Section With FX4CNF060 Indoor Section 265ANA060-- B Outdoor Section With FX4CNF060 Indoor Section Products Guide Specifications General