9. Set Linear Correction

NOTE: Setting Linear Correction should be done in MM (metric) mode, not inches. This will ensure accurate readings for table movement.

Step 1: Press

Display

......................[default]

Step 2: Enter the value between 0.0001 and 9.9999.

Step 3: Press

to confirm or press

 

to clear.

10. Enter Parameter Setttings Mode

With this function, you can select each parameter to be locked or unlocked. When a parameter is locked, then the end-user can only see the value, but cannot change it.

Step 1: Press

Display

Step 2: Enter the password.

Step 3: Use

to scroll through the parameters.

Step 4: Press

to lock or unlock.

 

On = unlock

 

 

Off = lock

 

 

Step 5: Press

to confirm or press

to clear.

29

Image 29
Contents Inch Planer Warranty Period Warranty and ServiceTable of Contents Page Page Introduction WP-2510 floor diagram Tefc induction, 1/2HP, 3PH, 60Hz SpecificationsUnpacking Contents of the Shipping ContainerDust Hood Installation and AssemblyVolt Operation Grounding InstructionsConverting from 230 Volt to 460 Volt AdjustmentsTest Run Controller Set-UpBelt Tension Feed RateOpening Hood Replacing or Rotating Knife InsertsAnti-Kickback Fingers Planer’s Feed SystemChipbreaker Pressure Bar Table Adjustments Feed Restriction Test Cutting and TroubleshootingClip Marks Lubrication MaintenanceOperation Front Panel Overview Controller M15S Operating InstructionsOperation Modes Manual ModeStart/Stop/Cancel Setting Target ValueExample Fast Program 10 sets Entering preset target valuesExecute Select Counting direction Select Positioning ModeSet Tolerances Set Software Limit Hi/Lo EndTo set low speed limit Set Low Speed LimitSet Linear Correction Enter Parameter Setttings ModeLoad Datum Values Check Software VersionExample Calibration Set Device Resolution13. IN/MM Conversion 16. M15S Troubleshooting Display 17. M15S Specifications 18. M15S Parameters Troubleshooting Planer Operating Problems Troubleshooting Mechanical and Electrical Problems Replacement Parts Column Assembly Index No. Part No Description Size Qty Parts List Column AssemblyWP2510-458 Gearbox Assembly Parts List Gearbox Assembly Parts List Cutterhead Assembly WP2510-254 Table Assembly Parts List Table Assembly Base Assembly Parts List Base Assembly WP2510-660 120 WP2510-6120 Parts List Top Cover Assembly Parts List Electrical Box Assembly Electrical Connections 230Volt Electrical Connections 460Volt New Sanford Rd LaVergne, Tennessee
Related manuals
Manual 56 pages 10.84 Kb