Kenmore 153.33616 Beangledslightlyinward, Position,drillasmallholethroughboththeventpipeand

Page 15

Toinsureproperventingofthisgas-firedwaterheater,the correctventpipediametermustbeutilized,Anyadditionsor deletionsofothergasappliancesonacommonventwiththis waterheatermayadverselyaffecttheoperationofthewater heater.Consultyourgassupplierif anysuchchangesare planned.

Forproperventingin certaininstallations,largerdiameter ventpipemaybenecessary,ConsultyourlocalSearsService Centerorgassupplierto aidyouindeterminingtheproper ventingforyourwaterheaterfromtheventtablesinthecurrent editionoftheNationalFuelGasCodeANStZ223,1/NFPA54,

Periodicallychecktheventingsystemforsignsofobstruction ordeteriorationandreplaceifneeded,

Thecombustionandventilationairflowmustnotbeobstructed,

Thewaterheaterwithdrafthoodinstalledmustbeconnected

toa chimneyorlistedventpipesystem,whichterminatesto theoutdoors,Neveroperatethewaterheaterunlessitisvented totheoutdoorsandhasadequateairsupplytoavoidrisksof improperoperation,explosionorasphyxiation,

Forproperdrafthoodattachment,thedrafthoodlegsmay

beangledslightlyinward,

Placethedrafthoodlegsinthereceivingholesonthetopof thewaterheaterThelegswillsnapintheholestogivea. tightfit.Securetwolegstotopwithsheetmetalscrews,

Placetheventpipeoverthedrafthood,Withtheventpipein

position,drillasmallholethroughboththeventpipeand

drafthood,Securethemtogetherwithasheetmetalscrew,

seeFigure17.

DRAFT HOOD

_V

VENT

$

DRAFT HOOD

All vent gases must be completely vented to the outdoors of the structure (dwelling), Install only the draft hood provided with the new water heater and no other draft hoed.

Vent pipes must be secured at each joint with sheet metal screws,

There must be a minimum of 6 inches (153 mm) clearance between single wall vent pipe and any combustible material. Fill and seal any clearance between single wall vent pipe and

combustible material with mortar mix, cement, or other noncombustible substance, For other than single wall, follow vent pipe manufacturer's clearance specifications, To insure a tight fit of the vent pipe in a brick chimney, seal around the vent pipe with mortar mix cement,

Failure to have required clearances between vent piping and combustible material will result in a fire hazard,

Be sure vent pipe is propedy connected to prevent escape of dangerous flue gases which could cause deadly asphyxiation.

Flue gases may escape if vent p_peis not connected

Do not store corrosive chemicals in vicini_ of water heater,

Chemical corrosion of flue and vent system can cause serious injuryor death.

Contact a qualified installer or service agency

Breathing carbon monoxide can cause brain damage ordeath Always read and understand instruction manual.

VENT TO OUTDOORS

INEY

OP,AFT HOOD

Chemical vapor corrosion of the flue and vent system may occur if air for combustion contains certain chemical vapors. Spray can propellants, cleaning solvents, refrigerator and air conditioner refrigerants, swimming pool chemicals, calcium and sodium chloride, waxes, bleach and process chemicals are typical compounds which are potentially corrosive.

FIGURE17.

Obstructed or deteriorated vent systems may present serious health risk or asphyxiation.

Gas Piping

The vent pipe from the water heater must be no less than the diameter of the draft hood outlet on the water heater and must

slope upward at least 1/4 inch per linear foot (21 mm per meter), see Figure 18,

CHfMNEY

FIGURE18.

Fire and Explosion Hazard

Do not use water heater with any gas other than the gas shown on the rating plate

, E×cessve pressure to gas control valve can cause serious

injury or death

,Turn off gas lines during installation

,Contact qualified installer or service agency

15

Image 15
Contents 153.336960 Gallon Propane Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.AModel no 153.336860 Gallon Propane 153.336900Death or injury Symbol indicates a potentially hazardousIndicates An imminently Could result in death or injuryFeel water before bathing or showering Improper installation and use may result Property damageFire Hazard Explosion HazardPage Model RecoveryDimensions Tank Type Rate GAL8 Ventpipe DiameterYou may or may not need all these tools, depending on your When Sweat SolderingMaterials Needed Basic Tools Additional Tools NeededTGO ThermostatSupplied by Customers Pilot & Main BurnerRemoving the Old Water Heater Property Damage Hazard Facts to Consider About LocationInsulation Blankets Front ViewOfdoor FIGUREll ALL AIR from Inside BuildingsHotter Water can Scald Water PipingLookatthetopofthewaterheaterThecoldwaterinlet.is Temperature-Pressure Relief ValveInstallationcompleted Using Installation KITWatertemperatureover125F Fee/waterbeforebathingor showeringFilling the Water Heater Gas Piping BeangledslightlyinwardPosition,drillasmallholethroughboththeventpipeand SeeFigure17Sediment Traps AgaslineofsufficientsizemustberuntothewaterheaterGAS Piping with Flexibleconnector GAS Control What to do if YOU Smell GASTemperature Regulation Burner Cleaning Tank Sediment Cleaning Burner InspectionDraining Temperature-Pressure Relief Valve OperationHousekeeping Anode Rod InspectionDrain Valve Washer Replacement ServiceCLOSEthecoldwaterinletvalvetothewaterheater Chart Start Up ConditionsBY-PASS Operational Conditions MakenecessaryairsupplychangestocorrectOperational Conditions Leakage Checkpoints Leaking T&P Valve Page Page Model Numbers BurnerassemblyWhen ORDERINGREPAIRPARTS,ALWAYSGIVETHE Following INFORNT1ON Key No. Part DescriptionBy calling 1-800-366-PART 1-800-366-7278. If the parts you Model Numbers Part Description 153.336400HA 153.3364649003474 9063457#37This ISA Repair Parts LIST, Nota Packing List Master Protection Agreements Limited Warranty on Tanks That LeakLimited Warranty on Parts Sears Installation Service