ThankYou for purchasing a Kenmore water heater. Propedy installed and maintained, it should give you years of trouble free service. If you should decide that you want the new water heater professionally installed by Sears call
Abbreviations Found In This Instruction Manual:
CSA - Canadian Standards Association ANSI - American National Standards Institute NFPA- National Fire Protection Association ASME - American Society of Mechanical Engineers GAMA - Gas Appliance Manufacturers Association
This
Standard for Gas Water Heaters ANSI Z21.10.1 • CSA 4.1 (current edition).
Read the "Safety Precautions" section, page 3 of this manual first and then the entire manual carefully. If you don'tfollow the safety rules, the water heater will not operate properly. It could cause DEATH, SERIOUS BODILY INJURY AND/OR PROPERTY DAMAGE.
This manual contains instructions for the installation, operation, and maintenance of the
pages, READ THE ENTIRE MANUAL BEFORE ATTEMPTING TO INSTALL OR OPERATE THE WATER HEATER.
•The installation must conform with these instructions and
the local code authority having jurisdiction. In the absence of local codes, installations shall comply with the following:
In the United States: The National Fuel Gas Code ANSI Z223.1/NFPA 54. This publication is available from the Canadian Standards Association, 8501 East Pleasant Valley Rd, Cleveland Ohio 44131, or The National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02269.
•If after reading this manual you have any questions or do not
understand any portion of the instructions, call the Sears Service Center.
•Carefully plan the place where you are going to put the water heater. Correct combustion, vent action, and vent pipe installation are very important in preventing death from possible carbon monoxide poisoning and fires. See figure 1.
Examine the location to ensure the water heater complies with the Facts to Consider About the Location section in this
manual.
•For California installation this water heater must be braced, anchored, or strapped to avoid falling or moving during an
earthquake. See instructions for correct installation procedures. Instructions may be obtained from your local dealer, wholesaler, public utilities or California Office of the State Architect, 400 P Street, Sacramento, CA 95814.
•Massachusetts Code requires this water heater to be installed in accordance with Massachusetts
•Complies with SCAQMD rule #1121 and districts having equivalent NOx requirements.
|
|
|
| RECOVERY | MINIMUM |
|
| DIMENSIONS | ||
| TANK | TYPE |
| RATE GAL8. | VENTPIPE | DIAMETER | IN INCHES (mm) | |||
MODEL | CAPACITY | OF | B'ru | PERHOUR | INCHES |
| INCHES | HEIGHTTO | ||
NUMBER | IN GALS (LTRS) | GAS | RATE | @ 90=F RISE | (mm) |
| (mm) | JACKETTOP | ||
153336160 | 30(114) | NATURAL | 32,000 | 32.8 | 3"(76)or | 4"(102) | 181/4"(464) | 433/4"(1,111) | ||
153.336260 | 40 (151) | NATURAL | 35,500 | 36.3 | 3" (76) or | 4" (102) | 20 | 1/4" (514) | 47 | 1/4" (1,200) |
153.336300 HA | 30(114) | NATURAL | 35,500 | 36.3 | 3"(76) | 15 3/4" (400) | 571/2"(1,461) | |||
153.336360 | 30(114) | NATURAL | 35,500 | 36.3 | 3"(76) | 153/4"(400) | 571/2"(1,461) | |||
153.336400 HA | 40 (151) | NATURAL | 35,500 | 36.3 | 3" (76) | 18 1/4" (464) | 55 1/2" (1,410) | |||
153.336464 | 40 (151) | NATURAL | 35,500 | 36.3 | 3" (76) | 18 1/4" (464) | 55 1/2" (1,410) | |||
153.336500 HA | 50 (189) | NATURAL | 35,500 | 36.3 | 3" (76) | 20 | 1/4" (514) | 56 | 1/2" (1,435) | |
153.336560 | 50 (189) | NATURAL | 35,500 | 36.3 | 3" (76) | 20 | 1/4" (514) | 56 | 1/2" (1,435) | |
153.336760 | 30(114) | PROPANE | 35,500 | 36.3 | 3"(76) | 153/4"(400) | 571/2"(1,461) | |||
153.336800 HA | 40 (151) | PROPANE | 35,500 | 36.3 | 3" (76) | 18 1/4" (464) | 55 | 1/2" (1,410) | ||
153.336860 | 40 (151) | PROPANE | 35,500 | 36.3 | 3" (76) | 18 1/4" (464) | 55 | 1/2" (1,410) | ||
153.336900 HA | 50 (189) | PROPANE | 35,500 | 36.3 | 3" (76) | 20 | 1/4" (514) | 56 | 1/2" (1,435) | |