Rangemaster Toledo FS Hob Technical Data, This hotplate is category II2H3+, Dimensions, Ratings

Models: Toledo FS Hob

1 24
Download 24 pages 46.75 Kb
Page 21
Image 21
Technical Data

Technical Data

The hotplate is an independent Class 3 built in unit.

This hotplate is category II2H3+

It is supplied set for group H natural gas. A conversion kit from NG to LP gas is packed with the hotplate.

INSTALLER: Please leave these instructions with the User.

DATA BADGE LOCATION : Base of the hotplate.

Country of Destination: GB/IE

Gas

 

Electric

Natural Gas

20mbar

220 - 240V 50Hz

Butane

29mbar

 

Propane

37mbar

 

(See appliance data badge for test pressures)

Dimensions

Overall width

1173mm

Overall depth

499mm

Space for fixing

See ‘Positioning of Hotplate’

Minimum space above hotplate

650mm

Connections

Gas:

Electric

Rp 1/2 at rear right-hand side

220 - 240V 50Hz

Ratings

 

 

 

 

 

 

Natural Gas

L.P. Gas

 

 

Hotplate

 

Injector

 

Injector

 

Wok burner

3.65kW

internal 80

3.5kW (255g/h)

internal 54

 

external 129

external 77

 

 

 

 

 

Large Burner

3.0kW

134

3.0kW (218g/h)

87

 

Medium Burners

1.7kW

109

1.7kW (124g/h)

68

 

Small Burner

1.0kW

75

1.0kW (73g/h)

51

Gas burner inputs based on Gross Calorific Value

Maximum total electrical load at 230V 50 W (approximate total)

21

U18900-02

Page 21
Image 21
Rangemaster Toledo FS Hob Technical Data, This hotplate is category II2H3+, Dimensions, Connections, Ratings, Natural Gas