WARNING - SERVICING TO BE CARRIED OUT ONLY BY AN AUTHORISED PERSON
Disconnect from electricity and gas before servicing. Check appliance is safe when you have finished.
Conversion to LP gas
Check in the Technical Data section at the back of the book that the hotplate is convertible to the gas you want to use.
This conversion must be performed by a competent person. After conversion the installation must comply with the relevant regulations and also the local electricity supply company requirements. Read the instructions before converting this appliance.
Failure to convert the appliance correctly could invalidate any warranty or liability claims and lead to prosecution.
This instruction must be used in conjunction with the rest of the appliance instruction, in particular for information on Standards, hotplate positioning, connection hose suitability etc.
When servicing or replacing
Do not use
Disconnect from the electricity supply before commencing servicing.
Before electrical
Injectors
Remove burner caps and heads. Remove old jets. Fit the new jets (see Technical Data section at the back of the book for correct jets). Reassemble in reverse order.
Tap adjustment
Disconnect from electricity supply.
Pull off all the control knobs and remove the two hexagon headed screws (which act as locators for the pan support), from the edge of the hotplate under the right hand pan support.
Slide the glass to the rightslightly and lift it from the side. Carefully lift it clear of the hotplate and place the panel somewhere safe. The tap bypass screws are now accessible once the bezel location brackets are removed.
Turn the bypass screw on each control clockwise to the stop.
Refit the glass panel and replace the fixing screws in the top edge of the hotplate.
Carefully replace the control sealing rings and replace the control knobs.
17 |