Bryant 213R warranty Physical Data, Unit Size --- Series

Page 3

PHYSICAL DATA

UNIT SIZE --- SERIES

018---A

024---A

030---A

036---A

042---A

048---A

060---A

Operating Weight (lb)

159

160

208

211

233

269

295

Shipping Weight (lb)

184

185

240

242

262

300

327

Compressor Type

 

 

 

Scroll

 

 

 

REFRIGERANT

 

 

Freon(R--- 22)

 

 

 

Control

 

 

TXV (R--- 22 Hard Shutoff)

 

 

 

Charge (lb)

5.5

6

7.5

8

10

14

15.5

COND FAN

 

 

Propeller Type, Direct Drive

 

 

Air Discharge

 

 

 

Vertical

 

 

 

Air Qty. (CFM)

2233

2614

2614

3334

3334

4046

4046

Motor HP

1/12

1/10

1/10

1/8

1/8

1/5

1/5

Motor RPM

800

1100

1100

800

800

800

800

COND COIL

 

 

 

 

 

 

 

Face Area (Sq. ft.)

15.09

15.09

25.87

22.63

17.6

22.63

25.15

Fins per In.

20

20

20

20

20

20

20

Rows

1

1

1

1

2

2

2

Circuits

5

6

6

6

7

8

9

VALVE CONNECT. (In. ID)

 

 

 

 

 

 

 

Vapor

5/8”

5/8”

3/4”

3/4”

7/8”

7/8”

7/8”

Liquid

 

 

 

3/8”

 

 

 

REFRIGERANT TUBES* (In. OD)

 

 

 

 

 

 

 

Vapor (0--- 80 Ft. Tube Length)

5/8”

5/8”

3/4”

3/4”

7/8”

7/8”

1--- 1/8”

Liquid (0--- 80 Ft. Tube Length)

 

 

 

3/8”

 

 

 

*For tubing sets between 80 and 200 ft. horizontal or 20 ft. vertical differential, consult the Longline Guideline. Note: See unit Installation Instruction for proper installation.

VAPOR LINE SIZING AND COOLING CAPACITY LOSS 1-STAGE HEAT PUMP APPLICATIONS

LONG LINE APPLICATION: An application is considered

 

is above indoor unit, and 60 ft. when the outdoor unit is below

”Long line” when the total equivalent tubing length exceeds 80

 

the indoor unit. Refer to Accessory Usage Guideline below for

ft. or when there is more than 20 Ft. vertical separation between

 

required accessories. See Long-Line Application Guideline for

indoor and outdoor units. These applications require additional

 

required piping and system modifications. Also, refer to the table

accessories and system modifications for reliable system

 

below for the acceptable vapor tube diameters based on the total

operation. The maximum allowable total equivalent length is 250

 

length to minimize the cooling capacity loss.

 

 

ft. The maximum vertical separation is 200 ft. when outdoor unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling Capacity Loss (%)

 

 

 

 

 

Acceptable Vapor

 

 

 

 

 

Total Equivalent Line Length (ft.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Unit Nominal Size (Btuh)

Line Diameter OD

Standard Application

 

 

 

 

Long Line Application

 

 

 

(in.)

 

 

 

 

Requires Accessories

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25

50

80

80+

100

125

150

175

200

225

250

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18000

5/8

0

1

1

 

1

2

3

3

4

5

5

6

R---22 HP

3/4

0

0

0

 

0

0

1

1

1

1

2

2

24000

5/8

0

1

3

 

3

3

5

6

7

8

9

10

R---22 HP

3/4

0

0

0

 

0

1

1

1

2

2

3

3

30000

3/4

0

1

1

 

1

2

3

3

4

5

5

6

R---22 HP

7/8

0

0

0

 

0

1

1

1

2

2

2

3

36000

3/4

0

1

2

 

2

3

4

5

6

7

8

9

R---22 HP

7/8

0

0

1

 

1

1

2

2

3

3

4

4

42000

7/8

0

1

1

 

1

2

2

3

4

4

5

5

R---22 HP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

48000

7/8

0

1

2

 

 

2

2

3

4

5

5

6

7

R---22 HP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60000

7/8

1

2

3

 

 

3

4

5

7

8

9

10

11

R---22 HP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 1/8

0

0

1

1

1

1

2

2

2

3

3

 

Standard Length = 80 ft. or less total equivalent length

Applications in this area are long line. Accessories are required as shown recommended on Long Line Application Guidelines

Applications in this area may have height restrictions that limit allowable total equivalent length, when outdoor unit is below indoor unit See Long Line Application Guidelines

213R

3

Image 3
Contents Product Data Features / BenefitsModel Number Nomenclature Standard FeaturesUnit Size --- Series Physical DataAccessories Accessory ThermostatsENT Applications Line Applications Accessory Usage GuidelineOutdoor Air Temperature Sensor Charging Subcooling TXV-TYPE Expansion Device Weighted Sound Power DBAWeighted Sound Power DBA with Sound Hood Electrical DataDimensions 213RNA,G Balance Point Worksheet Series Combination RatingsCNRV*2414A 22,800 Unit Size CNRH*3617A 28,400 FK4DNB006 CAR**4224A 40,500 CSRH*4212A 41,000 CNRH*6024A 45,500 213RNA018---A Outdoor Section With FA4CNF018 Indoor Section Detailed Cooling Capacities213RNA024---A Outdoor Section With FA4CNC024 Indoor Section 1125 213RNA030---A Outdoor Section With FA4CNF030 Indoor Section875 10001350 213RNA036---A Outdoor Section With FC4DNF036 Indoor Section1050 12001400 MBtuh† System Total Sens213RNA042---A Outdoor Section With FC4DNF042 Indoor Section 12251800 System MBtuh† Total Sens‡213RNA048--A Outdoor Section With FC4DNF048 Indoor Section 16002250 213RNA060---A Outdoor Section With FC4DNF060 Indoor Section1750 2000Heat Pump Heating Performance 213RNA018---A Outdoor Section With FA4CNF018 Indoor SectionFC4DNF018 FC4DNF024 FF1ENE018 FF1ENE024 FK4DNF001 FK4DNF002 213RNA024---A Outdoor Section With FA4CNC024 Indoor Section 213RNA030---A Outdoor Section With FA4CNF030 Indoor Section FK4DNF002 FK4DNF003 FK4DNF005 213RNA036---A Outdoor Section With FC4DNF036 Indoor SectionFK4DNB006 FK4DNF003 FK4DNF005 213RNA042---A Outdoor Section With FC4DNF042 Indoor SectionFK4DNB006 FK4DNF005 213RNA048-A Outdoor Section With FC4DNF048 Indoor SectionFK4DNB006 213RNA060---A Outdoor Section With FC4DNF060 Indoor SectionProducts Guide Specifications General