Accessory Description and Usage (Listed Alphabetically) - CONTINUED

213R

11. Outdoor Air Temperature Sensor

Designed for use with Bryant Thermostats listed in this publication. This device enables the thermostat to display the outdoor temperature. This device also is required to enable special thermostat features such as auxiliary heat lock out.

Usage Guideline:

Suggested for all Bryant thermostats listed in this publication.

12. Outdoor Thermostat

An SPDT temperature-actuated switch which turns on supplemental electric heaters when outdoor air temperature drops below a user-selected set point.

Usage Guideline:

Electric supplemental heat applications in non-variable speed indoor units when electric heat staging is desired.

Usage Guideline:

Some local codes may require limiting the heating head pressure in the vapor line in some applications.

13. Secondary Outdoor Thermostat

An SPDT temperature-actuated switch which turns on third-stage of supplemental electric heaters when outdoor air temperature drops below the second-stage set point.

Usage Guideline:

Outdoor thermostat applications where electric heater is capable of 3-stage operation.

14. Sound Hood

Wraparound sound reducing cover for the compressor. Reduces the sound level up to 2 dBA.

Usage Guideline:

Suggested when unit is installed closer than 15 ft to quiet areas, bedrooms, etc.

Suggested when unit is installed between two houses less than 10 ft apart.

Usage Guideline:

Suggested in the following applications:

Heat pump installations in heavy snowfall areas. Heat pump installations in snowdrift locations.

Heat pump installations in areas of prolonged subfreezing temperatures.

All commercial installations.

15. Thermostatic Expansion Valve (TXV) Bi-Flow

Amodulating flow-control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator.

Usage Guideline:

Required in all heat pump applications

16. Time-Delay Relay

An SPST delay relay which briefly continues operation of indoor blower motor to provide additional cooling after the compressor cycles off.

Note: Most indoor unit controls include this feature. For those that do not, use the guideline below.

Usage Guideline:

6

Image 6
Contents Features / Benefits Product DataStandard Features Model Number NomenclaturePhysical Data Unit Size --- SeriesAccessory Thermostats AccessoriesAccessory Usage Guideline ENT Applications Line ApplicationsOutdoor Air Temperature Sensor Electrical Data Weighted Sound Power DBAWeighted Sound Power DBA with Sound Hood Charging Subcooling TXV-TYPE Expansion DeviceDimensions 213RNA,G Balance Point Worksheet Combination Ratings SeriesCNRV*2414A 22,800 Unit Size CNRH*3617A 28,400 FK4DNB006 CAR**4224A 40,500 CSRH*4212A 41,000 CNRH*6024A 45,500 Detailed Cooling Capacities 213RNA018---A Outdoor Section With FA4CNF018 Indoor Section213RNA024---A Outdoor Section With FA4CNC024 Indoor Section 1000 213RNA030---A Outdoor Section With FA4CNF030 Indoor Section875 11251200 213RNA036---A Outdoor Section With FC4DNF036 Indoor Section1050 13501225 MBtuh† System Total Sens213RNA042---A Outdoor Section With FC4DNF042 Indoor Section 14001600 System MBtuh† Total Sens‡213RNA048--A Outdoor Section With FC4DNF048 Indoor Section 18002000 213RNA060---A Outdoor Section With FC4DNF060 Indoor Section1750 2250Heat Pump Heating Performance 213RNA018---A Outdoor Section With FA4CNF018 Indoor SectionFC4DNF018 FC4DNF024 FF1ENE018 FF1ENE024 FK4DNF001 FK4DNF002 213RNA024---A Outdoor Section With FA4CNC024 Indoor Section 213RNA030---A Outdoor Section With FA4CNF030 Indoor Section 213RNA036---A Outdoor Section With FC4DNF036 Indoor Section FK4DNF002 FK4DNF003 FK4DNF005213RNA042---A Outdoor Section With FC4DNF042 Indoor Section FK4DNB006 FK4DNF003 FK4DNF005213RNA048-A Outdoor Section With FC4DNF048 Indoor Section FK4DNB006 FK4DNF005213RNA060---A Outdoor Section With FC4DNF060 Indoor Section FK4DNB006Guide Specifications General Products