Envision Peripherals Geothermal Indoor Split Heat Pumps installation manual Equipment Selection

Page 5

ENVISION SERIES INSTALLATION MANUAL

General Installation Information (continued)

small, as in replacement of heating only systems, larger ductwork should be installed. All existing ductwork should be checked for leaks and repairs made accordingly. The duct systems and diffusers should be sized to handle the design airflow quietly. If air noise or excessive airflow is a problem, the blower speed can be changed to a lower speed to reduce airflow. This will reduce the performance of the unit slightly in heating; however, it will increase the temperature rise across the air coil. Airflow must still meet minimum requirements.

Equipment Selection

The following guidelines should be used when mating an Envision Split to an air handler/coil.

Select R-410A components only.

Select 12 SEER or higher air handler/coil.

Match the air handler to the air handler coil data table on page 9.

Indoor matching adjustable TXV should be used with any air handler/coil. Fixed orifice or cap tube systems should not be used.

Utilizing Existing Coil or Air Handler

It is recommended that a new R-410A air handler be installed with an Envision Split considering the long term ben- efits of reliability, warranty, etc. versus the short term installation cost savings. However, the existing air handler may be retained provided the following:

Coil currently is R-410A rated

Coil uses a TXV. No capillary or fixed orifice systems should be used

A life expectancy of more than 7 years remaining for the air handler and components

Image 5
Contents 410A Refrigerant Ton Single Speed Ton Dual Capacity Envision Series Geothermal Indoor Split Heat PumpsModel Nomenclature Physical CharacteristicsTable of Contents General Installation Information Utilizing Existing Coil or Air Handler Equipment SelectionConnection to Air Coil Air Handler InstallationDual Fuel Systems Swivel Connections Residential Units Water PipingLine Set Sizes Air Handler Coil DataEnvision Matching Air Coil Surface Rows TubeSolenoid Valve Open Loop Well Water SystemsWater Quality Solenoid WiringMultiple Units on One Flow Center Closed Loop Ground Source SystemsWater Tank Preparation Desuperheater ConnectionsDesuperheater Startup Plumbing InstallationElectrical Thermostat WiringGeneral Electrical Data24V Accessory relay see SW2 3 for description of operation Wiring SchematicsHp Total Microprocessor Control Lockout Conditions Cooling OperationFan G only STG1 STG2 STG3 Emerg Single Speed Units Operation Logic DataFreeze Sensing Setting DIP Switch SettingsRefrigeration Position Description System ServiceSystem Evacuation Leak TestingInitial System Charge Calculation Charging the SystemDetermining Subcooling Pressure/Temperature Coversion Chart for R-410A Single Speed Models Unit Operating ParametersDual Capacity Models Startup Steps Before Powering Unit, Check The FollowingUnit Startup Final Evaluation Heating Cycle Analysis Unit Startup/TroubleshootingDual Capacity Pressure Drop and Recommended Flow RatesSingle Speed LED Definitions and Diagnostics TroubleshootingStandard Microprocessor Controls Refrigerant SystemsReplacement Procedures Preventive MaintenanceEnvision NZ Split Dimensional Data Physical DimensionsInstallation Notes

Geothermal Indoor Split Heat Pumps specifications

Envision Peripherals has established itself as a leader in the energy-efficient heating and cooling market with its advanced geothermal indoor split heat pumps. These systems are designed to utilize the earth's stable underground temperature as a renewable energy source, resulting in remarkable performance and sustainability.

One of the main features of Envision Peripherals geothermal indoor split heat pumps is their exceptional energy efficiency. With the ability to achieve a coefficient of performance (COP) exceeding 4.0, these heat pumps provide four units of heating or cooling for every unit of electricity consumed. This level of efficiency significantly reduces operational costs and lowers environmental impact, making them an ideal choice for eco-conscious consumers.

The technology employed in these systems emphasizes reliability and flexibility. The heat pumps are equipped with variable speed compressors, allowing them to adjust the heating and cooling output based on the current demands of the space. This results in consistent indoor temperatures and enhanced comfort. Moreover, the systems can seamlessly integrate with existing HVAC infrastructures, offering versatile installation options for residential and commercial applications.

Another characteristic that sets Envision Peripherals geothermal systems apart is their dual functionality. These units not only provide heating during the colder months but also excel in cooling during hot weather conditions. The geothermal heat pumps extract heat from the indoor air and transfer it to the ground, ensuring an efficient cooling process without the need for traditional air conditioning systems.

Durability and low maintenance are key aspects of Envision Peripherals heat pumps. Constructed with high-quality materials and advanced engineering, these systems are built to withstand varying environmental conditions. They feature a closed-loop system that minimizes wear and tear, reducing the frequency of repairs and providing homeowners and businesses with peace of mind.

In addition, Envision Peripherals emphasizes eco-friendliness. The use of renewable geothermal energy diminishes dependence on fossil fuels, contributing to a more sustainable living and working environment. Their commitment to sustainability aligns with global efforts to reduce greenhouse gas emissions and combat climate change.

In summary, Envision Peripherals geothermal indoor split heat pumps deliver exemplary energy efficiency, advanced technology, and a range of benefits, including dual functionality and reduced environmental impact. As the demand for sustainable heating and cooling solutions continues to grow, these systems represent a leading choice for consumers seeking comfort and energy savings.