. A complete Parts List is available at www.MillerWelds.com
9-6. Troubleshooting Tables
A. Welding
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Trouble |
|
|
| Remedy | ||||||
|
|
| |||||||||
Low or no weld output; generator pow- |
| Check control settings. | |||||||||
er output okay at ac receptacles. |
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| Check weld connections. | ||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| Check fuse F1, and replace if open (see Section | ||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| Have Factory Authorized Service Agent check brushes, slip rings, integrated rectifiers SR2 and SR3, | ||
|
|
|
|
|
|
|
|
| and main rectifier SR1. | ||
|
| ||||||||||
No weld output or generator power out- | Be sure all equipment is disconnected from receptacles when starting unit. | ||||||||||
put at ac receptacles. |
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| Check fuses F1 and F2, and replace if open (see Section | ||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| Check plug PLG6 connection. | ||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| Have Factory Authorized Service Agent check brushes, slip rings, and integrated rectifiers SR2, SR3. | ||
|
|
| |||||||||
Low weld output. |
| Check control settings. | |||||||||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| Check fuse F1, and replace if open (see Section | ||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| Check engine speed, and adjust if necessary (see Section | ||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| Service air cleaner (see Section | ||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| Have Factory Authorized Service Agent check brushes, slip rings, and integrated rectifiers SR2, SR3. | ||
|
|
| |||||||||
High weld output. |
| Check control settings. | |||||||||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| Check engine speed, and adjust if necessary (see Section | ||
|
|
| |||||||||
Erratic weld output. |
| Check control settings. | |||||||||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| Tighten and clean connections to electrode and workpiece. | ||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| Use dry, | ||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| Remove excessive coils from weld cables. | ||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| Clean and tighten connections both inside and outside welding generator. | ||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| Check engine speed, and adjust if necessary (see Section | ||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| Have Factory Authorized Service Agent check brushes, slip rings, and integrated rectifiers SR2, SR3. | ||
|
|
|
|
|
|
|
|
|
|
|
|
B. Generator Power
Trouble | Remedy | |
|
| |
No or low generator power output at ac | Reset supplementary protectors (see Section | |
receptacles; weld output okay. |
| |
Press optional GFCI receptacle Reset button (see Section | ||
| ||
|
| |
| Check fuse F2, and replace if open (see Section | |
|
| |
| Check engine ignition wiring connections. | |
|
| |
| Have Factory Authorized Service Agent check brushes, slip rings, and integrated rectifier SR3. | |
|
| |
No generator power or weld output. | Be sure all equipment is disconnected from receptacles when starting unit. | |
|
| |
| Check fuses F1 and F2, and replace if open (see Section | |
|
| |
| Check engine ignition wiring connections. | |
|
| |
| Have Factory Authorized Service Agent check brushes, slip rings, and integrated rectifiers SR2 and | |
| SR3. | |
|
|