SECTION 14 − GENERATOR POWER GUIDELINES
.The views in this section are intended to be representative of all
14-1. Selecting Equipment
1
2
1Generator Power Receptacles − Neutral Bonded To Frame
2
3
.Be sure equipment has double
insulated symbol and/or word- ing on it.
! Do not use
3
OR
gen_pwr 2007−04 − Ref.
14-2. Grounding Generator To Truck Or Trailer Frame
! Always ground generator frame to vehicle frame to pre- vent electric shock and static electricity hazards.
! Also see AWS Safety & Health Fact Sheet No. 29, Grounding of Portable And Vehicle Mounted Welding Generators.
|
| 1 | Equipment Grounding |
|
|
| Terminal (On Front Panel) |
|
| 2 | Grounding Cable (Not |
| 1 |
| Supplied) |
| 3 | Metal Vehicle Frame | |
|
| ||
GND/PE | 2 | Connect cable from equipment | |
|
| ground terminal to metal vehicle | |
|
| frame. Use #10 AWG or larger | |
|
| insulated copper wire. |
3 | . |
|
! |
Electrically bond generator
frame to vehicle frame by met-
Bed liners, shipping skids, and some running gear insu- late the welding generator from the vehicle frame. Al- ways connect a ground wire from the generator equip- ment grounding terminal to bare metal on the vehicle frame as shown.
! If unit does not have GFCI re- ceptacles, use