3-8. Optional Meter Circuit Board Settings
1 2
XMeans switch position does not affect specified function.
. Means switch must be in this position.
Voltage Sensing Function
Arc Voltage Sensing Using Voltage Sensing
Lead For Welding Power Source That Does
Not Support Pins F And H
1 | 2 | 3 | 4 | 5 |
Or
Arc Voltage Sensing Using Feedback From
Welding Power Source That Does Support
Pins F And H
1 | 2 | 3 | 4 | 5 |
Tools Needed:
1/4 in
1Meter Circuit Board
2DIP Switch S2
3Potentiometer R18
4Receptacle RC16
Wiring harness with
For voltage feedback from voltage sensing lead, connect plug PLG43 from unit wiring harness to PLG42.
For voltage feedback from welding power source to wire feeder
1
2
Digital Meter Display
Meters/Minute
1 | 2 | 3 | 4 | 5 |
Or
Inches/Minute
1 2 3 4 5
801