Table 7-1. Drive Roll And Wire Guide Kits (2 Drive Roll)

NOTE

Base selection of drive rolls upon the following recommended usages:

1.V-Grooved rolls for hard wire.

2.U-Grooved rolls for soft and soft shelled cored wires.

3.U-Cogged rolls for extremely soft shelled wires (usually hard surfacing types).

4.V-Knurled rolls for hard shelled cored wires.

5.Drive roll types may be mixed to suit particular requirements (example: V-Knurled roll in combination with U-Grooved).

Wire Diameter

 

Kit No.

Drive Roll

Inlet

 

 

 

 

 

Wire Guide

Fraction

Decimal

Metric

Part No.

Type

 

 

 

 

 

 

 

.023/.025 in

.023/.025 in

0.6 mm

087 131

087 130

V-Grooved

056 192

.030 in

.030 in

0.8 mm

079 594

053 695

V-Grooved

056 192

.035 in

.035 in

0.9 mm

079 595

053 700

V-Grooved

056 192

.040 in

.040 in

1.0 mm

161 189

053 696

V-Grooved

056 192

.045 in

.045 in

1.2 mm

079 596

053 697

V-Grooved

056 193

 

 

 

 

 

 

 

.052 in

.052 in

1.3 mm

079 597

053 698

V-Grooved

056 193

1/16 in

.062 in

1.6 mm

079 598

053 699

V-Grooved

056 195

 

 

 

 

 

 

 

.035 in

.035 in

0.9 mm

044 749

072 000

U-Grooved

056 192

 

 

 

 

 

 

 

.045 in

.045 in

1.2 mm

079 599

053 701

U-Grooved

056 193

 

 

 

 

 

 

 

.052 in

.052 in

1.3 mm

079 600

053 702

U-Grooved

056 193

 

 

 

 

 

 

 

1/16 in

.062 in

1.6 mm

079 601

053 706

U-Grooved

056 195

5/64 in

.079 in

2.0 mm

079 602

053 704

U-Grooved

056 195

 

 

 

 

 

 

 

.035 in

.035 in

0.9 mm

079 606

132 958

V-Knurled

056 192

 

 

 

 

 

 

 

.045 in

.045 in

1.2 mm

079 607

132 957

V-Knurled

056 193

.052 in

.052 in

1.3 mm

079 608

132 956

V-Knurled

056 193

1/16 in

.062 in

1.6 mm

079 609

132 955

V-Knurled

056 195

 

 

 

 

 

 

 

.068-.072 in

.068-.072 in

1.8 mm

089 984

132 959

V-Knurled

056 195

 

 

 

 

 

 

 

5/64 in

.079 in

2.0 mm

079 610

132 960

V-Knurled

056 195

 

 

 

 

 

 

 

.045 in

.045 in

1.2 mm

083 318

083 489

U-Cogged

056 193

 

 

 

 

 

 

 

.052 in

.052 in

1.3 mm

083 317

083 490

U-Cogged

056 193

 

 

 

 

 

 

 

1/16 in

.062 in

1.6 mm

079 614

053 708

U-Cogged

056 195

 

 

 

 

 

 

 

5/64 in

.079 in

2.0 mm

079 615

053 710

U-Cogged

056 195

 

 

 

 

 

 

 

S-0157-C

OM-186 895 Page 27

Image 31
Contents Processes OM-186 895GDescription From Miller to You Table of Contents Standards DirectivesElectric Shock can kill Symbol UsageMarks a special safety message Arc Welding HazardsBuildup of GAS can injure or kill ARC Rays can burn eyes and skinWelding can cause fire or explosion Flying Metal can injure eyesPrincipal Safety Standards About Pacemakers EMF InformationLES Fumées ET LES GAZ peuvent être dangereux Signification des symboles− Consignes DE Securite − Lire Avant Utilisation UN Choc Électrique peut tuerLE Bruit peut affecter l’ouïe LE Soudage peut provoquer un incendie ou une explosionDES Particules Volantes peuvent blesser les yeux DES Pièces Chaudes peuvent pro- voquer des brûlures gravesDES Organes Mobiles peuvent provoquer des blessures Risque D’INCENDIE OULA Chute DE L’APPAREIL peut blesser ’EMPLOI Excessif peutInformation sur les champs électromagnétiques Principales normes de sécuritéConsignes relatives aux stimulateurs cardiaques − Definitions + +Rating Label For CE Products Symbols And DefinitionsSpecifications − InstallationSite Selection Gun Recommendation Table Equipment Connection DiagramsPin Receptacle, Shielding Gas And Optional Volt Sense Lead Pin Receptacle Information Connecting Welding Gun And Weld CableVoltage Sensing Function Optional Meter Circuit Board SettingsDigital Meter Display Motor Start/Burnback Control Installing Wire Guide And Drive Roll Installing And Threading Welding Wire Front Panel Controls − OperationOptional Side Panel Controls − Maintenance & TroubleshootingRoutine Maintenance Disconnect power before maintainingOverload Protection TroubleshootingCircuit Diagram For Wire Feeder With Optional Equipment − Electrical DiagramMain Assembly − Parts ListPLG1 Optional Drive Assembly, Wire 2 Drive Roll -1 Item Drive Assembly, Wire4 Drive Roll -1 Item Drive Roll And Wire Guide Kits 2 Drive Roll Drive Roll & Wire Guide Kits 4 Drive Roll OM-186 895 OM-186 895 Support ServiceMiller Electric Mfg. Co Owner’s Record