Nortel Networks 555-7101-215 manual Connecting the server to power, Before you begin

Models: 555-7101-215

1 64
Download 64 pages 22.96 Kb
Page 52
Image 52

Installing the server and connecting the peripheral devices

Standard 1.0

Connecting the server to power

Before you begin

Ensure that proper power and grounding are available for all the power outlets serving the CallPilot server and its associated peripherals. Power for these devices must be wired and fused independently of all other receptacles and referenced to the same ground as the PBX system.

Aqualified electrician must implement the single-point ground reference as required between the power outlets of the CallPilot server and the power outlets of the switch.

Provide a sufficient number of properly grounded power outlets or power bars for all equipment.

For more information, refer to Chapter 2, “Grounding and power requirements”, in the CallPilot Planning and Engineering Guide.

52

CallPilot

Page 52
Image 52
Nortel Networks 555-7101-215 manual Connecting the server to power, Before you begin