Miller Electric I-22A & I-24A manual Drive Roll & Wire Guide Kits 4 Drive Roll

Page 32

Table 7-2. Drive Roll & Wire Guide Kits (4 Drive Roll)

NOTE

Base selection of drive rolls upon the following recommended usages:

1.V-Grooved rolls for hard wire.

2.U-Grooved rolls for soft and soft shelled cored wires.

3.U-Cogged rolls for extremely soft shelled wires (usually hard surfacing types).

4.V-Knurled rolls for hard shelled cored wires.

5.Drive roll types may be mixed to suit particular requirements (example: V-Knurled roll in combination with U-Grooved).

Wire Diameter

 

Kit No.

Drive Roll

Wire Guide

Fraction

Decimal

Metric

Part No.

Type

Inlet

Intermediate

 

 

 

 

 

 

 

 

 

.023/.025 in

.023/.025 in

0.6 mm

087 132

087 130

V-Grooved

056 192

056 206

 

 

 

 

 

 

 

 

.030 in

.030 in

0.8 mm

046 780

053 695

V-Grooved

056 192

056 206

.035 in

.035 in

0.9 mm

046 781

053 700

V-Grooved

056 192

056 206

.040 in

.040 in

1.0 mm

191 917

053 696

V-Grooved

056 192

056 206

.045 in

.045 in

1.2 mm

046 782

053 697

V-Grooved

056 193

056 207

 

 

 

 

 

 

 

 

.052 in

.052 in

1.3 mm

046 783

053 698

V-Grooved

056 193

056 207

1/16 in

.062 in

1.6 mm

046 784

053 699

V-Grooved

056 195

056 209

 

 

 

 

 

 

 

 

.035 in

.035 in

0.9 mm

044 750

072 000

U-Grooved

056 192

056 206

 

 

 

 

 

 

 

 

.045 in

.045 in

1.2 mm

046 785

053 701

U-Grooved

056 193

056 207

 

 

 

 

 

 

 

 

.052 in

.052 in

1.3 mm

046 786

053 702

U-Grooved

056 193

056 207

 

 

 

 

 

 

 

 

1/16 in

.062 in

1.6 mm

046 787

053 706

U-Grooved

056 195

056 209

5/64 in

.079 in

2.0 mm

046 788

053 704

U-Grooved

056 195

056 209

 

 

 

 

 

 

 

 

.035 in

.035 in

0.9 mm

046 792

132 958

V-Knurled

056 192

056 206

.045 in

.045 in

1.2 mm

046 793

132 957

V-Knurled

056 193

056 207

.052 in

.052 in

1.3 mm

046 794

132 956

V-Knurled

056 193

056 207

 

 

 

 

 

 

 

 

1/16 in

.062 in

1.6 mm

046 795

132 955

V-Knurled

056 195

056 209

 

 

 

 

 

 

 

 

.068-.072 in

.068-.072 in

1.8 mm

089 985

132 959

V-Knurled

056 195

056 209

5/64 in

.079 in

2.0 mm

046 796

132 960

V-Knurled

056 195

056 209

 

 

 

 

 

 

 

 

.045 in

.045 in

1.2 mm

083 319

083 489

U-Cogged

056 193

056 207

.052 in

.052 in

1.3 mm

083 320

083 490

U-Cogged

056 193

056 207

1/16 in

.062 in

1.6 mm

046 800

053 708

U-Cogged

056 195

056 209

5/64 in

.079 in

2.0 mm

046 801

053 710

U-Cogged

056 195

056 209

Ref. S-0025-D

OM-186 895 Page 28

Image 32
Contents Description OM-186 895GProcesses From Miller to You Table of Contents Directives StandardsSymbol Usage Marks a special safety messageArc Welding Hazards Electric Shock can killARC Rays can burn eyes and skin Welding can cause fire or explosionFlying Metal can injure eyes Buildup of GAS can injure or killPrincipal Safety Standards EMF Information About PacemakersSignification des symboles − Consignes DE Securite − Lire Avant UtilisationUN Choc Électrique peut tuer LES Fumées ET LES GAZ peuvent être dangereuxLE Soudage peut provoquer un incendie ou une explosion DES Particules Volantes peuvent blesser les yeuxDES Pièces Chaudes peuvent pro- voquer des brûlures graves LE Bruit peut affecter l’ouïeRisque D’INCENDIE OU LA Chute DE L’APPAREIL peut blesser’EMPLOI Excessif peut DES Organes Mobiles peuvent provoquer des blessuresConsignes relatives aux stimulateurs cardiaques Principales normes de sécuritéInformation sur les champs électromagnétiques + + − DefinitionsSymbols And Definitions Rating Label For CE ProductsSite Selection − InstallationSpecifications Pin Receptacle, Shielding Gas And Optional Volt Sense Lead Equipment Connection DiagramsGun Recommendation Table Connecting Welding Gun And Weld Cable Pin Receptacle InformationDigital Meter Display Optional Meter Circuit Board SettingsVoltage Sensing Function Motor Start/Burnback Control Installing Wire Guide And Drive Roll Installing And Threading Welding Wire − Operation Front Panel Controls− Maintenance & Troubleshooting Routine MaintenanceDisconnect power before maintaining Optional Side Panel ControlsTroubleshooting Overload Protection− Electrical Diagram Circuit Diagram For Wire Feeder With Optional Equipment− Parts List Main AssemblyPLG1 Optional Drive Assembly, Wire 2 Drive Roll -1 Item Drive Assembly, Wire4 Drive Roll -1 Item Drive Roll And Wire Guide Kits 2 Drive Roll Drive Roll & Wire Guide Kits 4 Drive Roll OM-186 895 OM-186 895 Service SupportOwner’s Record Miller Electric Mfg. Co