Miller Electric I-22A & I-24A manual Installing And Threading Welding Wire

Page 21

3-11. Installing And Threading Welding Wire

1 2 3

1Retaining Ring

2Hub Tension Adjustment Nut

If necessary, move hub on support for use of different size wire spool.

Remove retaining ring, and install spool so hub pin fits spool hole. Reinstall retaining ring.

Adjust tension nut so wire is taut when wire feed stops.

3Pressure Assembly Adjustment Knob

Lay gun cable out straight.

AOpen pressure assembly, hold wire tightly, and cut off end. Push wire through guides into gun.

BClose and tighten pressure assembly. Press JOG button until wire comes out gun.

CTo adjust drive roll pressure,

press gun trigger to feed wire against wood surface. Tighten knob so wire does not slip.

Cut off wire. Close door.

AB

C

Tighten

WOOD

Tools Needed:

15/16 in

Ref. 801 924-B / S-0627-A

OM-186 895 Page 17

Image 21
Contents OM-186 895G ProcessesDescription From Miller to You Table of Contents Standards DirectivesMarks a special safety message Symbol UsageArc Welding Hazards Electric Shock can killWelding can cause fire or explosion ARC Rays can burn eyes and skinFlying Metal can injure eyes Buildup of GAS can injure or killPrincipal Safety Standards About Pacemakers EMF Information− Consignes DE Securite − Lire Avant Utilisation Signification des symbolesUN Choc Électrique peut tuer LES Fumées ET LES GAZ peuvent être dangereuxDES Particules Volantes peuvent blesser les yeux LE Soudage peut provoquer un incendie ou une explosionDES Pièces Chaudes peuvent pro- voquer des brûlures graves LE Bruit peut affecter l’ouïeLA Chute DE L’APPAREIL peut blesser Risque D’INCENDIE OU’EMPLOI Excessif peut DES Organes Mobiles peuvent provoquer des blessuresPrincipales normes de sécurité Information sur les champs électromagnétiquesConsignes relatives aux stimulateurs cardiaques − Definitions + +Rating Label For CE Products Symbols And Definitions− Installation SpecificationsSite Selection Equipment Connection Diagrams Gun Recommendation TablePin Receptacle, Shielding Gas And Optional Volt Sense Lead Pin Receptacle Information Connecting Welding Gun And Weld CableOptional Meter Circuit Board Settings Voltage Sensing FunctionDigital Meter Display Motor Start/Burnback Control Installing Wire Guide And Drive Roll Installing And Threading Welding Wire Front Panel Controls − OperationRoutine Maintenance − Maintenance & TroubleshootingDisconnect power before maintaining Optional Side Panel ControlsOverload Protection TroubleshootingCircuit Diagram For Wire Feeder With Optional Equipment − Electrical DiagramMain Assembly − Parts ListPLG1 Optional Drive Assembly, Wire 2 Drive Roll -1 Item Drive Assembly, Wire4 Drive Roll -1 Item Drive Roll And Wire Guide Kits 2 Drive Roll Drive Roll & Wire Guide Kits 4 Drive Roll OM-186 895 OM-186 895 Support ServiceMiller Electric Mfg. Co Owner’s Record