Simer Pumps 3963 owner manual Electrical, Do Not Mount Vertically

Page 3

Electrical

3

Flow

Directional

Arrow

115V Properly

Grounded

Outlet

2" Checkvalve

Do Not Mount

Vertically

Sump Pit

2" Discharge

Pipe

30"

Be sure the

 

float switch can

 

swing through

 

it's entire arc.

 

Drill a 3/16"

 

vent hole here.

 

Install pump on

 

a hard, level surface.

 

18"

Figure 1

Piping – Sewage Applications (2" or Less Solids)

In any case, piping must not be smaller than pump discharge.

When installed in a sewage system, pipe must be capable of handling semi-solids of at least 2” (5.1 cm) diameter.

The rate of flow in the discharge pipe must keep any solids present in suspension in the fluid. To meet mini- mum flow requirements (2 feet (.6 m) per second in dis- charge line), size pipe as follows:

A Pipe Size Of:

Will Handle a Flow Rate Of:

1-1/2” (3.8 cm)

12 GPM (45 LPM)

2” (5.1 cm)

21 GPM (79 LPM)

2-1/2” (6.3 cm)

30 GPM (113 LPM)

3” (7.6 cm)

48 GPM (181 LPM)

NOTICE: Use Teflon™ tape on pipe connections. Do not use ordinary pipe joint compound on plastic pipe or pump. Pipe joint compound can attack plastics and dam- age pump.

3.To reduce motor noise and vibrations, a short length of rubber hose (1-5/8"(41mm) I.D., e.g. radiator hose) can be connected into discharge line near pump using suitable clamps.

TM E.I. DuPont de Nemours and Company Corporation.

4.If the pump discharge line is exposed to outside sub- freezing atmosphere, then the portion of line exposed must be installed so any water remaining in pipe will drain to outfall by gravity. Failure to do this can cause water trapped in discharge to freeze which could result in damage to pump.

5.Install a 2” check valve in the horizontal portion of the discharge pipe. Make certain, the flow indicating arrow, points away from the pump. This check valve will keep the water from either running back into the basin or into the area being pumped out when the pump is not running. Check valve should be a free flow valve that will easily pass solids.

NOTICE: For best performance of check valve when handling solids, do not install it with discharge angled more than 45° above the horizontal. Do not install check valve in a vertical position as solids may settle in valve and prevent opening on startup.

6.Drill a 3/16” (4.7mm) hole in discharge pipe about 1"-2” (2.5 - 5.1cm) above pump discharge connec- tion (but below check valve) to prevent airlocking the pump.

7.Insert the float switch piggy-back plug into a proper- ly grounded outlet and the pump plug into the piggy- back plug.

8.Check the installation by observing the pump opera- tion through one complete cycle. Make sure that no parts of the assembly interfere with the float switch.

Risk of flooding. May cause personal injury or property damage. Failure to make this operational check may lead to improper operation, premature fail- ure, and flooding.

ELECTRICAL

Hazardous voltage. Can shock, burn, or cause death. When installing, operating, or servicing this pump, follow safety instructions listed below.

1.DO NOT splice the electrical power cord.

2.DO NOT allow electrical cord plug to be submerged.

3.DO NOT use extension cords. They are a fire hazard and can reduce voltage sufficiently to prevent pump- ing and/or damage motor.

4.DO NOT handle or service pump while it is connected to power supply.

5.DO NOT remove grounding prong from plug or mod- ify plug.To protect against electrical shock, the power cord is a three-wire conductor and includes a

3-prong grounded plug. Plug pump into a 3-wire, grounded, grounding-type receptacle. Connect pump according to electrical codes that apply.

For parts or assistance, call Simer Customer Service at 1-800-468-7867 /1-800-546-7867

Image 3
Contents Bomba sumergibles para el manejo de sólidos Pitmaster MODSpecifications Safety / Specifications / Performance / InstallationRead and Follow Safety Instructions InstallationElectrical ElectricalDo Not Mount Vertically Cord Lift Warning Operation / ServiceService OperationTroubleshooting Troubleshooting / Repair PartsLimited Warranty WarrantySécurité / Specifications / Rendement / Installation Lire Toutes CES Instructions ET LES SuivreRendement Électricité ÉlectricitéAvertissement Concernant LE Levage PAR LE Cordon Électrique Fonctionnement / EntretienFonctionnement EntretienLocalisation DES Pannes Localisation des pannes / Liste des pièces de rechangeGarantie Garantie LimitéeModalités et conditions générales Especificaciones Instructions de seguridad / Especificaciones / RendimientoLEA Y Siga LAS Instrucciones DE Seguridad InstalaciónInstalación Eléctrica Instalación / ÉléctricaAdvertencia Sobre EL Levantamiento POR Medio DEL Cordón Operación / ServicoOperación ServicoGuía Para LA Resolución DE Problemas Guía para la resolución de problemasGarantía Garantía LimitadaTérminos y condiciones generales

3963 specifications

Simer Pumps has established a reputation for reliability and innovation, and the Simer Pumps 3963 model exemplifies this commitment. Designed for versatility and efficiency, the 3963 model serves both residential and commercial applications, providing users with a powerful solution for various pumping needs.

One of the standout features of the Simer Pumps 3963 is its robust motor. The pump is equipped with a heavy-duty electric motor that ensures durability and longevity. This high-performance motor delivers a superior flow rate, making it suitable for tasks ranging from draining pools to managing groundwater. It operates quietly, which adds to the overall comfort of its application in both residential and commercial environments.

The 3963 model employs advanced technology, including a thermoplastic construction that enhances resistance to corrosion and wear. This material choice makes the pump ideal for handling various fluids, including clean water, wastewater, and light chemicals. Additionally, the model boasts an engineered design that minimizes energy consumption while maximizing output, ensuring that users can benefit from its efficiency without incurring excessive operating costs.

A significant characteristic of the Simer Pumps 3963 is its automatic on/off switch, which provides a hands-free experience. This feature includes a built-in float switch that detects water levels and triggers the pump when necessary, ensuring that the area remains dry without user intervention. This technology is particularly beneficial for sump applications, where the risk of flooding is present.

The model also features easy installation processes, allowing users to set it up with minimal hassle. The pump is designed with standard connections that fit various piping systems, ensuring compatibility and ease of integration. Furthermore, maintenance is straightforward; the pump’s accessible design allows for quick troubleshooting and service, minimizing downtime.

In summary, the Simer Pumps 3963 is an exemplary model that combines innovative technology with robust design to meet the diverse needs of its users. Its powerful motor, durable materials, energy-efficient operation, and user-friendly features make it a reliable choice for those seeking a dependable pumping solution. Whether for residential use or in commercial settings, the Simer Pumps 3963 stands out as a top-tier option in the market.