Miller Electric OM-2241 manual Remote 14 Receptacle RC8 Information

Page 18

3-9. Remote 14 Receptacle RC8

Y Turn off power before con- necting to receptacle.

1 Remote 14 Receptacle RC8 Connect feeder to RC8.

1

A

J

B

K

I

 

 

C

L N

H

D

M

G

 

E

F

Ref. 800 166-D

3-10. Remote 14 Receptacle RC8 Information

 

Socket

Information

 

A

24 volts ac. Protected by circuit breaker CB2.

24 VOLTS AC

B

Contact closure to A completes 24 volts ac contactor control circuit.

 

 

C

Command reference; 0 to +10 volts dc.

REMOTE OUTPUT CONTROL

D

Remote control circuit common.

 

E

0 to +10 volts dc input command signal from remote control.

 

F

Current feedback; 1 volt per 100 amperes.

 

H

Voltage feedback; 1 volt per 10 arc volts.

115 VOLTS AC

I

115 volts, 15 amperes, 60 Hz ac. Protected by circuit breaker CB1.

J

Contact closure to I completes 115 volts ac contactor control circuit.

 

GND

K

Chassis common.

G

Circuit common for 24 and 115 volts ac circuits.

 

REMOTE POWER ON/OFF

*

To remote On/Off switch.

 

 

REMOTE VOLTAGE SENSING

*

Voltage sensing signal from Negative (−) weld output terminal.

*

Voltage sensing signal from Positive (+) weld output terminal.

 

* Not Used

 

 

OM-2241 Page 14

Image 18 Contents
OM-2241 ProcessesDescription From Miller to You Table of Contents Page Arc Welding Hazards Symbol UsageMarks a special safety message Electric Shock can killFlying Metal can injure eyes ARC Rays can burn eyes and skinWelding can cause fire or explosion Buildup of GAS can injure or killCalifornia Proposition 65 Warnings Principal Safety Standards EMF InformationAbout Pacemakers Identifie un message de sécurité particulier − Consignes DE Sécurité − À Lire Avant UtilisationLES Pièces Chaudes peuvent cau- ser des brûlures graves LE Soudage peut causer un incen- die ou une explosionLES Particules Projetées peu- vent blesser les yeux LE Bruit peut affecter l’ouïe’EMPLOI Excessif peut Faire Risque D’INCENDIE OU D’EXPLOLA Chute DE L’APPAREIL peut blesser LES Pièces Mobiles peuvent cau- ser des blessuresPrincipales normes de sécurité Information sur les champs électromagnétiquesConsignes relatives aux stimulateurs cardiaques 230 SpecificationsDuty Cycle And Overheating OverheatingVolt-Ampere Curves Tipping Be careful when placing or moving unit over uneven surfacesSelecting a Location Movement Location And AirflowWeight Dimensions And WeightsDimensions VAC Receptacle And Circuit BreakersWeld Output Terminals And Selecting Cable Sizes 10 − 60% 60 − 100%Duty Cycle Remote 14 Receptacle RC8 Information Turn off power before con- necting to receptacleRemote 14 Receptacle RC8 InformationInput Voltage Electrical Service GuidePlacing Jumper Links Input Amperes At Rated OutputConnecting Input Power Welding Power Source Input Power ConnectionsDisconnect Device Input Power Con- nections Routine Maintenance Disconnect input power before maintaining MonthsControls Disconnect input power be- fore opening rear access door Fuse F1Short Circuit Shutdown Troubleshooting Table Trouble Remedy− Electrical Diagram OM-2241 − Parts List 1Main Assembly 2Panel, Front w/Components -1Item Rectifier, Si Diode SR1 1754Panel, Rear w/Components -1Item Service SupportOwner’s Record Miller Electric Mfg. Co