6-5. Troubleshooting
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Trouble |
| Remedy | |
|
|
|
|
|
No weld output; unit completely inop- | Place line disconnect switch in On position (see Section | |||
erative. |
|
| ||
|
|
|
|
|
|
|
| Check and replace line fuse(s), if necessary, or reset circuit breaker (see Section | |
|
|
|
|
|
|
|
| Check for proper input power connections (see Section | |
|
|
|
|
|
No weld output; meter display On. | Check, repair, or replace remote control. | |||
|
|
|
|
|
|
|
| Unit overheated. Allow unit to cool with fan On (see Section | |
|
|
|
|
|
Erratic or improper weld output. | Use proper size and type of weld cable (see Section | |||
|
|
|
|
|
|
|
| Clean and tighten all weld connections. | |
|
|
|
|
|
No 115 volts ac output at duplex recep- | Reset circuit breaker CB1 (see Section | |||
tacle, Remote 14 receptacle. |
|
| ||
|
|
|
|
|
No 24 volts ac output at Remote 14 re- | Reset circuit breaker CB2 (see Section | |||
ceptacle. |
|
| ||
|
|
|
|
|