Installation / Operation | 4 |
Hazardous voltage. Can shock, burn or cause death. Pump should always be electrically grounded to a suitable electrical ground such as a grounded water pipe or a properly grounded metallic raceway, or ground wire system. Do not cut off round ground pin.
6.If the pump discharge line is exposed to an outside
7.Check the system operation by observing the pump operation through one complete cycle.
Risk of flooding. Failure to make this operational check may lead to improper operation, premature failure, and flooding.
OPERATION
Hazardous voltage. Can shock, burn or
cause death. Do not handle a pump or pump motor with wet hands or when standing on wet or damp surface, or in water.
Before attempting to check why a unit has stopped oper- ating, disconnect power from the unit.
1.The shaft seal depends on water for lubrication and cooling. Do not operate the pump unless it is sub- merged in water as seal may be damaged if allowed to run dry.
2.The pump will not remove all water. On a flat surface Model Nos. 2300, C2300, 2305, 2310, C2310 and 2305G will pump down to within 1/8" of the pump- ing surface. Model No. 2355 will pump down to within 5/8" of the pumping surface.
NOTICE: For continuous operation, the pump must be submerged to prevent the motor from overheating. A fully submerged pump is preferred for proper cool- ing when a pump runs continuously.
AIRLOCKS
When a pump airlocks, it runs but does not move any water. An airlock will cause the pump to overheat and fail. The
If you suspect an airlock, unplug the pump, clean out the
Dewater flat roofs
Roofs
EmptyBasementsflooded rooms
3696 0500 NEW
Troubleshooting
SYMPTOM | PROBABLE CAUSE(S) | CORRECTIVE ACTION |
Pump won’t start or run. | Pump is not plugged in. | Check and see if pump is plugged in to a proper outlet. |
| Blown fuse. | If blown, replace with fuse of proper size or reset breaker. |
| Low line voltage. | If voltage is under recommended minimum. Check size of |
|
| wiring from main switch on property. If OK, contact power |
|
| company or hydro authority. |
| Defective motor. | Replace pump. |
|
|
|
Pump operates but | Restricted discharge | Remove pump and clean pump and piping. |
delivers little or no water. | (obstacle or ice in piping). |
|
| Restricted intake. | Remove the pump and clean out the intake screen. |
| Low line voltage. | The voltage is under recommended minimum. Check size of |
|
| wiring from main switch on property. If OK, contact power |
|
| company or hydro authority. |
| Worn or plugged impeller. | Replace pump. |
| The | Turn off the pump, clean out the |
|
| restart the pump. |
For parts or assistance, call Simer Customer Service at