Miller Electric 652, 812 manual Fumes and Gases can be hazardous, ARC Rays can burn eyes and skin

Page 6

FUMES AND GASES can be hazardous.

Welding produces fumes and gases. Breathing these fumes and gases can be hazardous to your health.

DKeep your head out of the fumes. Do not breathe the fumes.

DIf inside, ventilate the area and/or use local forced ventilation at the arc to remove welding fumes and gases.

DIf ventilation is poor, wear an approved air-supplied respirator.

DRead and understand the Material Safety Data Sheets (MSDSs) and the manufacturer’s instructions for metals, consumables, coatings, cleaners, and degreasers.

DWork in a confined space only if it is well ventilated, or while wearing an air-supplied respirator. Always have a trained watch- person nearby. Welding fumes and gases can displace air and lower the oxygen level causing injury or death. Be sure the breath- ing air is safe.

DDo not weld in locations near degreasing, cleaning, or spraying op- erations. The heat and rays of the arc can react with vapors to form highly toxic and irritating gases.

DDo not weld on coated metals, such as galvanized, lead, or cadmium plated steel, unless the coating is removed from the weld area, the area is well ventilated, and while wearing an air-supplied respirator. The coatings and any metals containing these elements can give off toxic fumes if welded.

ARC RAYS can burn eyes and skin.

Arc rays from the welding process produce intense visible and invisible (ultraviolet and infrared) rays that can burn eyes and skin. Sparks fly off from the weld.

DWear an approved welding helmet fitted with a proper shade of fil- ter lenses to protect your face and eyes when welding or watching (see ANSI Z49.1 and Z87.1 listed in Safety Standards).

DWear approved safety glasses with side shields under your helmet.

DUse protective screens or barriers to protect others from flash, glare and sparks; warn others not to watch the arc.

DWear protective clothing made from durable, flame-resistant mate- rial (leather, heavy cotton, or wool) and foot protection.

WELDING can cause fire or explosion.

Welding on closed containers, such as tanks, drums, or pipes, can cause them to blow up. Sparks can fly off from the welding arc. The flying sparks, hot workpiece, and hot equipment can cause fires and

burns. Accidental contact of electrode to metal objects can cause sparks, explosion, overheating, or fire. Check and be sure the area is safe before doing any welding.

DRemove all flammables within 35 ft (10.7 m) of the welding arc. If this is not possible, tightly cover them with approved covers.

DDo not weld where flying sparks can strike flammable material.

DProtect yourself and others from flying sparks and hot metal.

DBe alert that welding sparks and hot materials from welding can easily go through small cracks and openings to adjacent areas.

DWatch for fire, and keep a fire extinguisher nearby.

DBe aware that welding on a ceiling, floor, bulkhead, or partition can cause fire on the hidden side.

DDo not weld on closed containers such as tanks, drums, or pipes, unless they are properly prepared according to AWS F4.1 (see Safety Standards).

DDo not weld where the atmosphere may contain flammable dust, gas, or liquid vapors (such as gasoline).

DConnect work cable to the work as close to the welding area as practical to prevent welding current from traveling long, possibly unknown paths and causing electric shock, sparks, and fire hazards.

OM-278 Page 2

DDo not use welder to thaw frozen pipes.

DRemove stick electrode from holder or cut off welding wire at contact tip when not in use.

DWear oil-free protective garments such as leather gloves, heavy shirt, cuffless trousers, high shoes, and a cap.

DRemove any combustibles, such as a butane lighter or matches, from your person before doing any welding.

DAfter completion of work, inspect area to ensure it is free of sparks, glowing embers, and flames.

DUse only correct fuses or circuit breakers. Do not oversize or by- pass them.

DFollow requirements in OSHA 1910.252 (a) (2) (iv) and NFPA 51B for hot work and have a fire watcher and extinguisher nearby.

FLYING METAL or DIRT can injure eyes.

DWelding, chipping, wire brushing, and grinding cause sparks and flying metal. As welds cool, they can throw off slag.

DWear approved safety glasses with side shields even under your welding helmet.

BUILDUP OF GAS can injure or kill.

DShut off shielding gas supply when not in use.

D Always ventilate confined spaces or use approved air-supplied respirator.

MAGNETIC FIELDS can affect Implanted

Medical Devices.

D Wearers of Pacemakers and other Implanted

Medical Devices should keep away.

DImplanted Medical Device wearers should consult their doctor and the device manufacturer before going near arc welding, spot welding, gouging, plasma arc cutting, or induction heating operations.

NOISE can damage hearing.

Noise from some processes or equipment can damage hearing.

DWear approved ear protection if noise level is high.

CYLINDERS can explode if damaged.

Shielding gas cylinders contain gas under high pressure. If damaged, a cylinder can explode. Since gas cylinders are normally part of the welding process, be sure to treat them carefully.

DProtect compressed gas cylinders from excessive heat, mechani- cal shocks, physical damage, slag, open flames, sparks, and arcs.

DInstall cylinders in an upright position by securing to a stationary support or cylinder rack to prevent falling or tipping.

DKeep cylinders away from any welding or other electrical circuits.

DNever drape a welding torch over a gas cylinder.

DNever allow a welding electrode to touch any cylinder.

DNever weld on a pressurized cylinder − explosion will result.

DUse only correct shielding gas cylinders, regulators, hoses, and fit- tings designed for the specific application; maintain them and associated parts in good condition.

DTurn face away from valve outlet when opening cylinder valve.

DKeep protective cap in place over valve except when cylinder is in use or connected for use.

DUse the right equipment, correct procedures, and sufficient num- ber of persons to lift and move cylinders.

DRead and follow instructions on compressed gas cylinders, associated equipment, and Compressed Gas Association (CGA) publication P-1 listed in Safety Standards.

Image 6
Contents Processes DescriptionFile Multi-Process From Miller to You Table of Contents Directives StandardsDecstat6/05 Electric Shock can kill Symbol UsageArc Welding Hazards HOT Parts can cause severe burnsWelding can cause fire or explosion Fumes and Gases can be hazardousARC Rays can burn eyes and skin Flying Metal or Dirt can injure eyesFalling Unit can cause injury Welding Wire can cause injuryFire or Explosion hazard Moving Parts can cause injuryEMF Information Principal Safety StandardsCalifornia Proposition 65 Warnings About Implanted Medical DevicesSymboles utilisés UNE Décharge Électrique peut entraîner la mortDES Pièces Chaudes peuvent provoquer des brûlures graves LES Fumées ET LES GAZ peuvent être dangereuxLE Soudage peut provoquer un in cendie ou une explosion Risque D’INCENDIE OU D’EXPLO- Sion LE Bruit peut endommager l’ouïeLES Bouteilles peuvent exploser si elles sont endommagées LA Chute DE L’APPAREIL peut blesserProposition californienne 65 Avertissements LES Fils DE Soudage peuvent provoquer des blessuresLE Soudage À L’ARC risque de provoquer des interférences Principales normes de sécurité Information EMFEn ce qui concerne les implants médicaux OM-278 General Precautionary Label − DefinitionsElectric Shock And Airflow Label Nameplate Safety SymbolsInput Connection Label ? aManufacturer’s Rating Label For CE Products Weee Label For Products Sold Within The EU− Installation Symbols And DefinitionsSpecifications Volt-Ampere Curves CC Mode CV ModeDuty Cycle And Overheating 100% Duty CycleSelecting a Location Movement Location And Airflow460 mm OM-278 Weight Dimensions And WeightsDimensions Holes FrontTipping VAC Receptacle And Supplementary ProtectorsWeld Output Terminals Connecting Weld Output Cables Selecting Cable SizesMig Gmaw Cable Connections Gas Flowmeter RegulatorMig Gmaw And Flux Cored Fcaw Cable Connections Turn Off power before making connectionsRear Wire Feeder Fcaw GaslessRemote 14 Receptacle RC8 Information To remote On/Off switchTIG Gtaw Cable Connections InformationConnecting Remote Control Electrical Service GuidePlacing Jumper Links Tools Needed Do not overtighten Jumper link nutsDisconnect Device Input Power Connec- tions Connecting Input PowerWelding Power Source Input Power Con- nections = GND/PE Earth Ground− Operation Controls Non CE ModelsControls CE Models Fuse F1 − Maintenance & TroubleshootingRoutine Maintenance Short Circuit ShutdownTroubleshooting Trouble Remedy− Electrical Diagram Circuit Diagram218 514-B − Parts List Recommended Spare PartsRecommended Spare Parts Page Page Service Your distributor also givesSupport For assistance in filing or settling claims, contact To locate a Distributor or Service Agency visitMiller Electric Mfg. Co Your distributor and/or equipment manufacturer’s