4-9. Selecting Cable Sizes
NOTICE − ARC WELDING can cause Electromagnetic Interference.
To reduce possible interference, keep weld cables as short as possible, close together, and down low, such as on the floor. Locate welding operation 100 meters from any sensitive electronic equipment. Be sure this welding machine is installed and grounded according to this manual. If interference still occurs, the user must take extra measures such as moving the welding machine, using shielded cables, using line filters, or shielding the work area.
|
|
| Total Cable (Copper) Length In Weld Circuit Not Exceeding |
| |||||
|
|
|
|
|
|
|
|
|
|
|
| 100 ft (30 m) Or Less | 150 ft | 200 ft | 250 ft | 300 ft | 350 ft | 400 ft | |
|
| (45 m) | (60 m) | (70 m) | (90 m) | (105 m) | (120 m) | ||
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
| Welding | 10 − 60% | 60 − 100% |
|
|
|
|
|
|
| Duty |
|
| 10 − 100% Duty Cycle |
|
| |||
| Amperes | Duty Cycle |
|
|
|
| |||
| Cycle |
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| 100 | 4 | 4 | 4 | 3 | 2 | 1 | 1/0 | 1/0 |
|
|
|
|
|
|
|
|
|
|
| 150 | 3 | 3 | 2 | 1 | 1/0 | 2/0 | 3/0 | 3/0 |
|
|
|
|
|
|
|
|
|
|
| 200 | 3 | 2 | 1 | 1/0 | 2/0 | 3/0 | 4/0 | 4/0 |
|
|
|
|
|
|
|
|
|
|
| 250 | 2 | 1 | 1/0 | 2/0 | 3/0 | 4/0 | ||
|
|
|
|
|
|
|
|
|
|
| 300 | 1 | 1/0 | 2/0 | 3/0 | 4/0 | |||
|
|
|
|
|
|
|
|
|
|
| 350 | 1/0 | 2/0 | 3/0 | 4/0 | ||||
|
|
|
|
|
|
|
|
|
|
| 400 | 1/0 | 2/0 | 3/0 | 4/0 | ||||
|
|
|
|
|
|
|
|
|
|
| 500 | 2/0 | 3/0 | 4/0 | |||||
|
|
|
|
|
|
|
|
|
|
| 600 | 3/0 | 4/0 | ||||||
|
|
|
|
|
|
|
|
|
|
| 700 | 4/0 | |||||||
|
|
|
|
|
|
|
|
|
|
| 800 | 4/0 | |||||||
|
|
|
|
|
|
|
|
|
|
*Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere. Contact your distributor for the mm2 equivalent weld cable sizes.
4-10. Connecting Weld Output Cables
4
| 1 |
|
|
|
|
| Do not place |
|
|
| anything between |
|
|
| weld cable terminal |
|
|
| and copper bar. |
| 2 |
|
|
Tools Needed: | 3 |
|
|
|
|
| |
3/4 in (19 mm) |
|
|
|
| Correct Installation | ||
! Turn off power before connecting to | 1 | Weld Output Terminal | |
weld output terminals. |
| 2 | Supplied Weld Output Terminal Nut |
! Failure to properly connect weld | 3 | Weld Cable Terminal | |
cables may cause excessive heat | 4 | Copper Bar | |
and start a fire, or damage your ma- | Remove supplied nut from weld output ter- | ||
chine. |
| minal. Slide weld cable terminal onto weld |
803
Incorrect Installation
output terminal and secure with nut so that weld cable terminal is tight against copper bar. Do not place anything between weld cable terminal and copper bar. Make sure that the surfaces of the weld cable terminal and copper bar are clean.